Macular Pigment Optical Density and Ocular Pulse Amplitude in Subjects with Different Axial Lengths and Refractive Errors
نویسندگان
چکیده
BACKGROUND The purpose of our study was to: (1) investigate the macular pigment optical density (MPOD) and ocular pulse amplitude (OPA) in subjects with different axial lengths (AL) and refractive errors (RE); (2) determine if there is a correlation between MPOD and OPA; and (3) evaluate whether MPOD and OPA depend on intraocular pressure (IOP). MATERIAL AND METHODS This study included 140 eyes of 70 subjects - 17 men and 53 women, aged 18 to 29 years (mean: 22.5 years; SD=2.8). Every examined person underwent a thorough eye examination including: visual acuity, anterior segment and fundus examination, keratometry, auto-refractometry, and MPOD, OPA, AL, and IOP measurements. The obtained results were analyzed statistically using Statistica 10 software. P values of <0.05 were considered statistically significant. RESULTS The following refractive errors were selected: emmetropia (34 eyes), hyperopia (18 eyes), low myopia (60 eyes), medium myopia (19 eyes), and high myopia (9 eyes). It has been established that the OPA increases with the rise in the spherical equivalents (SE) (Rs=+0.38, P<0.001), while the increase in AL correlates with the decrease of OPA (Rs=-0.40, P<0.001). The increase in IOP correlates with the rise in the OPA (Rs=+0.20, P<0.05). There were no significant correlations between IOP and SE or AL. CONCLUSIONS (1) MPOD is not correlated with the OPA in subjects with different AL and RE; (2) OPA decreases with the rise of AL; (3) OPA decreases with the fall of the SE; and (4) OPA increases with the rise in IOP.
منابع مشابه
Macular pigment and ocular biometry
This study is designed to investigate the relationship between macular pigment optical density (MPOD) and ocular biometric parameters. The following details were recorded for 180 healthy subjects: demographic profile; best-corrected visual acuity; refractive status; ocular biometric parameters [axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and vitreous chamber depth (VCD)...
متن کاملمقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت
Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...
متن کاملPulsatile ocular blood flow study: decreases in exudative age related macular degeneration.
BACKGROUND Pulsatile ocular blood flow (POBF) is a parameter for evaluating choroidal blood flow. POBF in the patients with non-exudative and exudative age related macular degeneration (AMD) was investigated. METHODS POBF, pulse amplitude (PA), systolic and diastolic blood pressures, intraocular pressure (IOP), refractive error, and axial length were compared among 10 patients with non-exudat...
متن کاملOptical Coherence Tomography Findings of Retinal Folds in Nanophthalmos
Aim. To report the optical coherence tomography (OCT) findings in three members of the same family with nanophthalmos associated with elevated papillomacular retinal fold. Methods. Complete ophthalmic examination as well as ultrasonography and OCT was performed in all patients. Results. Axial lengths ranged from 16.75 mm to 17.48 mm and refractive errors ranged from +17.50 D to +20.50 D. Main f...
متن کاملChoroidal Blood Flow Change in Eyes with High Myopia
PURPOSE To evaluate choroidal blood flow changes in eyes with high myopia according to the pulsatile components of ocular blood flow analysis. METHODS A total of 104 subjects (52 males and 52 females) were included in this study. One eye of each participant was randomly selected and assigned to one of four refractive groups, designated as, hyperopes (n = 20; refractive error, ≥+1.00 diopter [...
متن کامل