A Stability-Indicating RP-HPLC Assay Method for 5-Fluorouracil
نویسندگان
چکیده
The present study describes the development of a validated RP-HPLC method for the determination of 5-fluorouracil in presence of its degradation products or other pharmaceutical excipients. Stress studies were performed on 5-fluorouracil and it was found that it degrades sufficiently in alkaline conditions, while negligible degradation was observed in acidic, neutral, oxidative and photolytic conditions. The peaks of the degradation products were not observed in the chromatogram due to the nonchromophoric nature of the degradation moiety formed. The separations were carried out on a C-18 reversed phase column (Phenomenex; Prodigy ODS3V, 250x4.6 mm, 5 mu) using 50mM KH(2)PO(4) (pH, 5.0) as mobile phase at a flow rate of 1.2 ml/min and temperature of 30 degrees . The wavelength of detection was 254 nm. A retention time of nearly 6 minutes was obtained. Analytical validation parameters such as specificity and selectivity, linearity, accuracy and precision were evaluated. The calibration curve for 5-fluorouracil was linear (r(2)=0.999+/-0.0005) from range of 10 mug/ml to 100 mug/ml. Relative standard deviation values for all the key parameters, was less than 2.0 %. The recovery of the drug after standard addition to the degraded sample was found to be 104.69%. Thus, the developed RP-HPLC method was found to be suitable for the determination of 5-fluorouracil in bulk as well as stability samples of the pharmaceutical dosage forms containing various excipients.
منابع مشابه
A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل