A simple and highly sensitive fluorescence assay for microRNAs.

نویسندگان

  • Wei Shen
  • Kiat Huei Yeo
  • Zhiqiang Gao
چکیده

Herein, we have reported a simple and highly sensitive fluorescence assay for the detection of microRNAs (miRNAs). The assay uses a duplex-specific nuclease (DSN) to amplify the fluorescence signal and magnetic beads (MBs) to completely remove the unreacted DNA detection probes. Briefly, fluorescein-capped DNA detection probes were first conjugated to the MBs. The use of the MBs produced a very low background signal since all the unreacted DNA probes can be conveniently removed from the solution by using a permanent magnet. During the assaying process, target miRNA strands hybridized with the DNA capture probes to form miRNA-DNA heteroduplexes. The DSN then selectively cleaved the DNA probes in the miRNA-DNA duplexes and release the target miRNA strands back into the solution, thereby establishing a target recycling amplification mechanism - a cumulative signal amplification process. A much-amplified fluorescence signal was obtained in the presence of traces of the target miRNA. In addition, a negligible background signal was conveniently attained by the complete removal of the unreacted DNA detection probes so that minute change in the fluorescence signal can be unambiguously detected. The negligible background signal in association with the accumulative signal amplification significantly lowered the detection limit and broadened the dynamic range of the assay. Moreover, the high specificity of the DSN to perfectly matched duplexes endowed this assay with good selectivity when analyzing target miRNAs with high sequence similarities. Successful attempts were made in applying the proposed assay to detect let-7a in total RNA extracted from cultured cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

-MicroRNAs: New biomarkers for diagnosing HIV-

According to the increasing number of AIDS patients and their deaths, Treatment is a very important debate to prevent this Which is dependent on early and Accurate diagnosis. Currently, there are different diagnostic methods, including virus cultures, rapid tests, western blot, and other tests for this infection. Among these, HIV RNA TESTING, especially APTIMA HIV RNA ASSAY and fourth generatio...

متن کامل

Highly sensitive and selective strategy for microRNA detection based on WS2 nanosheet mediated fluorescence quenching and duplex-specific nuclease signal amplification.

MicroRNAs (miRNAs) play vital roles in physiologic and pathologic processes and are significant biomarkers for disease diagnostics and therapeutics. However, rapid, low-cost, sensitive, and selective detection of miRNAs remains a challenge because of their short length, sequence homology, and low abundance. Herein, we report for the first time that WS2 nanosheet can exhibit differential affinit...

متن کامل

Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier

Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 6  شماره 

صفحات  -

تاریخ انتشار 2015