Balloon angioplasty for the treatment of coronary in-stent restenosis: immediate results and 6-month angiographic recurrent restenosis rate.
نویسندگان
چکیده
OBJECTIVES The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.
منابع مشابه
Six-month angiographic outcome after successful repeat percutaneous intervention for in-stent restenosis.
BACKGROUND In-stent restenosis is an increasing clinical problem. Discordant results have been published regarding the risk of recurrent restenosis after repeat angioplasty for the treatment of in-stent restenosis. METHODS AND RESULTS One hundred three consecutive patients (107 vessels) underwent repeat percutaneous intervention for the treatment of in-stent restenosis and were entered in a p...
متن کاملClinical and angiographic outcome in patients with in-stent restenosis and repeat target lesion revascularisation in small coronary arteries.
OBJECTIVE To evaluate the clinical and angiographic outcome in patients with in-stent restenosis in small coronary arteries and repeat target lesion revascularisation. DESIGN Patients with in-stent restenosis in coronary arteries < or = 2.85 mm were eligible for the study and underwent target lesion revascularisation. Clinical and angiographic variables were assessed during a six month follow...
متن کاملSirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis: a randomized controlled trial.
CONTEXT In patients with de novo coronary lesions, drug-eluting stents have drastically reduced restenosis risk compared with bare metal stents and conventional balloon angioplasty. It is less clear whether drug-eluting stents are superior to conventional balloon angioplasty for the treatment of patients with in-stent restenosis. OBJECTIVES To assess if drug-eluting stents are a more effectiv...
متن کاملStent placement compared with balloon angioplasty for small coronary arteries: in-hospital and 6-month clinical and angiographic results.
BACKGROUND Stenting has been demonstrated to be superior to balloon angioplasty in de novo focal lesions located in large native vessels. However, in small vessels, the benefit of stenting remains questionable. METHODS AND RESULTS A total of 381 symptomatic patients with de novo focal lesion located on a small coronary segment vessel (<3 mm) were randomly assigned to either stent implantation...
متن کاملA comparison of systematic stenting and conventional balloon angioplasty during primary percutaneous transluminal coronary angioplasty for acute myocardial infarction. STENTIM-2 Investigators.
OBJECTIVES In a multicenter, randomized trial, systematic stenting using the Wiktor stent was compared to conventional balloon angioplasty with provisional stenting for the treatment of acute myocardial infarction (AMI). BACKGROUND Primary angioplasty in AMI is limited by in-hospital recurrent ischemia and a high restenosis rate. METHODS A total of 211 patients with AMI <12 h from symptom o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 32 4 شماره
صفحات -
تاریخ انتشار 1998