The first detailed examination of flow injection-capillary electrophoresis (FI-CE) active parameters and their interactions via response surface methodology (RSM) is presented. Specifically, RSM in the form of a Box-Behnken design was implemented to effectively predict the significance of capillary length, voltage and injection volume on the optimization of an in-house built FI-CE analyzer. Initial studies were performed assessing peak height and peak shape of the model compound N,N-dimethylformamide. Optimum model conditions were then derived and used in the model separation of two small molecules, nicotinamide adenine dinucleotide, reduced form (NADH) and benzenesulfonamide. By implementing the RSM approach, detailed examination of active FI-CE parameters was possible, including the ability to reveal a significant interactive effect. This work is not only highly significant for advancing FI-CE developments, but instructive for investigators actively exploring other coupled analytical techniques and associated experimental parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis

Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Cyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis

Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 29 18  شماره 

صفحات  -

تاریخ انتشار 2008