The mucosal attachment at different abutments

نویسندگان

  • T. Berglundh
  • P. - O. Glantz
  • J. Lindhe
چکیده

The present experiment was performed to exatnine if the material used in the abutment part of an implant system influenced the quality of the mucosal barrier that formed following implant installation. 5 beagle dogs were included in the study. The mandibular premolars and the 1st. 2nd and 3rd maxillary premolars were extracted. Three fixtures of the Branemark System® were installed in each mandibular quadrant (a total of 6 fixtures per animal). Abutment connection was performed after 3 months of healing. In each dog the following types of abutments were used: 2 •'control abutments'" (c.p. titanium). 2 "ceramic abutments" (highly sintered AUOj), 1 "gold abutment", and 1 "short titanium abutment". This "short titanium abutment" was provided with an outer structure made of dental porcelain fused to gold. Following abutment connection a plaque control program was initiated and maintained for 6 months. The animals were sacrificed and perfused with a fixative. The mandibles were removed and each implant region was dissected, demineralized in EDTA and embedded in EPON*. Semithin sections representing the mesial, distal, buccal and lingual aspects of the peri-implant tissues were produced and subjected to histological examination. The findmgs from the analysis demonstrated that the material used in the abutment portion of the implant infiuenced the location and the quality of the attachment that occurred between the periimplant mucosa and the implant. Abutments made of c.p. titanium or ceramic allowed the formation of a mucosal attachment which included one epithelial and one connective tissue portion that were about 2 mm and 11.5 mm high, respectively. At sites where abutments made of gold alloy or denta! porcelain were used, no proper attachment formed at the abutment level, but the soft tissue margin receded and bone resorption occurred. The abutment fixture junction was hereby occasionally exposed and the mucosal barrier became established to the fixture portion of the implant. It was suggested that the observed differences were the result of varying adhesive properties of the materials studied or by variations m their resistance to corrosion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft tissue integration to dental implants

Soft tissue integration to dental implants Maria Welander Department of Periodontology, Institute of Odontology The Sahlgrenska Academy at University of Gothenburg, Box 450, 405 30 Göteborg, Sweden. Soft tissue integration is a prerequisite for implant success. The role of the soft tissue barrier at implants is to provide an effective seal that protects the underlying bone and prevents access f...

متن کامل

Implant Supported Distal Extension over Denture Retained by Two Types of Attachments. A Comparative Radiographic Study by Cone Beam Computed Tomography

BACKGROUND This study was conducted to compare and evaluate the effect of two different attachments (locator attachment and ball and socket [B&S] attachment) on implants and natural abutments supporting structures, in cases of limited inter-arch spaces in mandibular Kennedy Class I implant supported removable partial over dentures by measuring the bone height changes through the cone beam radio...

متن کامل

The mucosal barrier at implant abutments of different materials.

OBJECTIVE The aim of the present study was to analyze the soft tissue barrier formed to implant abutments made of different materials. MATERIAL AND METHODS Six Labrador dogs, about 1 year old, were used. All mandibular premolars and the first, second and third maxillary premolars were extracted. Three months later four implants (OsseoSpeed, 4.5 x 9 mm, Astra Tech Dental, Mölndal, Sweden) were...

متن کامل

Clinical outcomes of implant abutments in the anterior region: a systematic review.

STATEMENT OF PROBLEM The clinical outcomes of anterior implant abutments are not well reported. Purpose of the Study To systematically review the existing literature to identify survival, mechanical, biological, and esthetic outcomes of anterior implant abutments. MATERIAL AND METHODS An electronic search was performed using PubMed/MEDLINE with specific search terms and predetermined criteria...

متن کامل

Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color.

PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005