Optimization of beam orientations and beam weights for conformal radiotherapy using mixed integer programming.

نویسندگان

  • Chuang Wang
  • Jianrong Dai
  • Yimin Hu
چکیده

An algorithm for optimizing beam orientations and beam weights for conformal radiotherapy has been developed. The algorithm models the optimization of beam orientations and beam weights as a problem of mixed integer linear programming (MILP), and optimizes the beam orientations and beam weights simultaneously. The application process of the algorithm has four steps: (a) prepare a pool of beam orientation candidates with the consideration of avoiding any patient-gantry collision and avoiding direct irradiation of organs at risk with quite low tolerances (e.g., eyes). (b) Represent each beam orientation candidate with a binary variable, and each beam weight with a continuous variable. (c) Set up an optimization problem according to dose prescriptions and the maximum allowed number of beam orientations. (d) Solve the optimization problem with a ready-to-use MILP solver. After optimization, the candidates with unity binary variables remain in the final beam configuration. The performance of the algorithm was tested with clinical cases. Compared with standard treatment plans, the beam-orientation-optimized plans had better dose distributions in terms of target coverage and avoidance of critical structures. The optimization processes took less than 1 h on a PC with a Pentium IV 2.4 GHz processor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming.

The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam...

متن کامل

Simultaneous optimization of beam orientations and beam weights in conformal radiotherapy.

A methodology for the concurrent optimization of beam orientations and beam weights in conformal radiotherapy treatment planning has been developed and tested on a cohort of five patients. The algorithm is based on a beam-weight optimization scheme with a downhill simplex optimization engine. The use of random voxels in the dose calculation provides much of the required speed up in the optimiza...

متن کامل

Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Selection of beam orientations in intensity-modulated radiation therapy using single-beam indices and integer programming.

While the process of IMRT planning involves optimization of the dose distribution, the procedure for selecting the beam inputs for this process continues to be largely trial-and-error. We have developed an integer programming (IP) optimization method to optimize beam orientation using mean organ-at-risk (MOD) data from single-beam plans. Two test cases were selected in which one organ-at-risk (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 48 24  شماره 

صفحات  -

تاریخ انتشار 2003