Pii: S0730-725x(99)00102-2
نویسندگان
چکیده
Exploratory data-driven methods such as Fuzzy clustering analysis (FCA) and Principal component analysis (PCA) may be considered as hypothesis-generating procedures that are complementary to the hypothesis-led statistical inferential methods in functional magnetic resonance imaging (fMRI). Here, a comparison between FCA and PCA is presented in a systematic fMRI study, with MR data acquired under the null condition, i.e., no activation, with different noise contributions and simulated, varying “activation.” The contrast-to-noise (CNR) ratio ranged between 1–10. We found that if fMRI data are corrupted by scanner noise only, FCA and PCA show comparable performance. In the presence of other sources of signal variation (e.g., physiological noise), FCA outperforms PCA in the entire CNR range of interest in fMRI, particularly for low CNR values. The comparison method that we introduced may be used to assess other exploratory approaches such as independent component analysis or neural network-based techniques. Crown Copyright r 2000. Published by Elsevier Science Inc.
منابع مشابه
Pii: S0730-725x(00)00154-5
We describe an MR-compatible ventilator that is computer controlled to generate a variety of breathing patterns, to minimize image degrading effects of breathing motion, and to support delivery of gas anesthesia and experimental inhalational gases. A key feature of this ventilator is the breathing valve that attaches directly to the endotracheal tube to reduce dead volume and allows independent...
متن کاملPii: S0730-725x(01)00428-3
The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...
متن کاملPii: S0730-725x(00)00153-3
In this study the noise sensitivity of various anisotropy indices has been investigated by Monte-Carlo computer simulations and magnetic resonance imaging (MRI) measurements in a phantom and 5 healthy volunteers. Particularly, we compared the noise performance of indices defined solely in terms of eigenvalues and those based on both the eigenvalues and eigenvectors. It is found that anisotropy ...
متن کاملPii: S0730-725x(00)00122-3
We investigated the effects of transcranial magnetic stimulation (TMS) coils and electroencephalographic (EEG) electrodes on T2*-weighted echo-planar images (EPI) at 2.0 T (gradient-echo EPI, mean TE 5 53 ms, 2 3 2 3 4 mm ). In comparison with anatomic gradient-echo images (3D FLASH, TE 5 4 ms, 1 3 1 3 1 mm), T2*-weighted EPI acquisitions of a water-filled spherical phantom revealed severe sign...
متن کاملPii: S0730-725x(01)00436-2
Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...
متن کامل