Impedance measurement to assess epicardial fat prior to RF intraoperative cardiac ablation: a feasibility study using a computer model.

نویسندگان

  • Ana González-Suárez
  • Fernando Hornero
  • Enrique J Berjano
چکیده

Radiofrequency (RF) cardiac ablation is used to treat certain types of arrhythmias. In the epicardial approach, efficacy of RF ablation is uncertain due to the presence of epicardial adipose tissue interposed between the ablation electrode and the atrial wall. We planned a feasibility study based on a theoretical model in order to assess a new technique to estimate the quantity of fat by conducting bioimpedance measurements using a multi-electrode probe. The finite element method was used to solve the electrical problem. The results showed that the measured impedance profile coincided approximately with the epicardial fat profile measured under the probe electrodes and also that the thicker the epicardial fat, the higher the impedance values. When the lateral fat width was less than 4.5 mm, the impedance values altered, suggesting that measurements should always be conducted over a sizeable fat layer. We concluded that impedance measurement could be a practical method of assessing epicardial fat prior to RF intraoperative cardiac ablation, i.e. 'to map' the amount of adipose tissue under the probe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catheter Ablation of Ventricular Epicardial Tissue

Background—Transthoracic epicardial catheter ablation is an emerging catheter ablation strategy being used clinically at increasing frequency. However, the efficacy of standard RF ablation on the epicardial surface of the heart is hindered by (1) the lack of convective cooling of the ablation electrode and (2) the varying presence of epicardial adipose tissue interposed between the ablation ele...

متن کامل

Mathematical Modeling of Epicardial RF Ablation of Atrial Tissue with Overlying Epicardial Fat

The efficacy of treating atrial fibrillation by RF ablation on the epicardial surface is currently under question due to the presence of epicardial adipose tissue interposed between the ablation electrode and target site (atrial wall). The problem is probably caused by the electrical conductivity of the fat (0.02 S/m) being lower than that of the atrial tissue (0.4-0.6 S/m). Since our objective...

متن کامل

Catheter ablation of ventricular epicardial tissue: a comparison of standard and cooled-tip radiofrequency energy.

BACKGROUND Transthoracic epicardial catheter ablation is an emerging catheter ablation strategy being used clinically at increasing frequency. However, the efficacy of standard RF ablation on the epicardial surface of the heart is hindered by (1) the lack of convective cooling of the ablation electrode and (2) the varying presence of epicardial adipose tissue interposed between the ablation ele...

متن کامل

Outcome of stand-alone thoracoscopic epicardial left atrial posterior box isolation with bipolar radiofrequency energy for longstanding persistent atrial fibrillation

INTRODUCTION Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction ...

متن کامل

Subxiphoid surgical approach for epicardial catheter-based mapping and ablation in patients with prior cardiac surgery or difficult pericardial access.

BACKGROUND Percutaneous epicardial mapping and ablation are successful in some patients with ventricular epicardial reentry circuits but may be impossible when pericardial adhesions are present, such as from prior cardiac surgery. The purpose of this study was to evaluate the feasibility of direct surgical exposure of the pericardial space to allow catheter epicardial mapping and ablation in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 31 11  شماره 

صفحات  -

تاریخ انتشار 2010