Toxicity detection of sodium nitrite, borax and aluminum potassium sulfate using electrochemical method.
نویسندگان
چکیده
Based on the inhibition effect on the respiratory chain activity of microorganisms by toxicants, an electrochemical method has been developed to measure the current variation of a mediator in the presence of microorganisms contacted with a toxicant. Microelectrode arrays were adopted in this study, which can accelerate the mass transfer rate of an analyte to the electrode and also increase the total current signal, resulting in an improvement in detection sensitivity. We selected Escherichia coli as the testee and the standard glucose-glutamic acid as an exogenous material. Under oxygen restriction, the experiments in the presence of toxicant were performed at optimum conditions (solution pH 7.0, 37 degrees C and reaction for 3 hr). The resulting solution was then separated from the suspended microorganisms and was measured by an electrochemical method, using ferricyanide as a mediator. The current signal obtained represents the reoxidation of ferrocyanide, which was transformed to inhibiting efficiency, IC50, as a quantitative measure of toxicity. The IC50 values measured were 410, 570 and 830 mg/L for sodium nitrite, borax and aluminum potassium sulfate, respectively. The results show that the toxicity sequence for these three food additives is consistent with the value reported by other methods. Furthermore, the order of damage degree to the microorganism was also observed to be: sodium nitrite > borax > aluminum potassium sulfate > blank, according to the atomic force microscopy images of E. coli after being incubated for 3 hr with the toxic compound in buffer solutions. The electrochemical method is expected to be a sensitive and simple alternative to toxicity screening for chemical food additives.
منابع مشابه
Effect of Boron-Zinc-Aluminum-Silicium Compounds on the Fire Performance of Ultra-Low Density Fiberboards
B-Zn-Si-Al compounds are modified Si-Al compounds made of sodium silicate, zinc sulfate, borax, and aluminum sulfate. They act as a fire retardant during the preparation of ultra-low density fiberboards (ULDFs). An orthogonal experiment was used to optimize the contents of the four compounds according to the limiting oxygen index. Fourier transform infrared spectroscopy was employed to prelimin...
متن کاملEffects of Potassium Sulfate [K2SO4] on The Element Contents, Polyphenol Content, Antioxidant and Antimicrobial Activities of Milk Thistle [Silybum Marianum]
BACKGROUND Silybum marianum L. (Milk thistle) is native to the Mediterranean basin and is now widespread throughout the world. It's sprout is used as a herbal medicine for the treatment of liver disease for centuries. The seeds of milk thistle contain silymarin, an isomeric mixture of flavonolignans [silybin, silychristin, and silydianin]. Silymarin acts as a strong anti-hepatotoxic. OBJECTIV...
متن کاملDetermining detection limits of aqueous anions using electrochemical impedance spectroscopy
Background: Pulsed amperometric detection is a relatively new method for detection of ions and especially nonelectrolytes such as carbohydrates in aqueous solutions. Pulsed amperometric detection relies on a redox reaction while electrochemical impedance simply measures the real and capacitive resistant of the solution. There is a correlation between the real impedance of a solution and the ion...
متن کاملEvaluation of Mutagenic Potentials of Some Food Additives by Ames Test
Some chemicals used by human such as food additives are mutagenic and mutagenicity effects analysis of them is very important because of considerable consumption by man. One of the most common methods used in the recognition of the chemicals' mutagenicity is Salmonella Typhimurium Reverse Mutation (Ames) test. The purpose of the present study is mutagenicity effects analysis of sodium nitrite, ...
متن کاملDevelopment of A New Electrochemical Sensor based on Zr-MOF/MIP for Sensitive Diclofenac Determination
In this study, a new molecularly imprinted polymer with nanoporous material of zirconium metal-organic frameworks (Zr-MOF/MIP) for diclofenac (DFC) measurement is presented. The Zr-MOF/MIP was prepared by electropolymerization method, the Zr-MOFs were used to increase electrode surface and the DFC and para- aminobenzoic acid (pABA) were used as template and functional monomer, respectively. Zr-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental sciences
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2013