A study of stereo microscope measurements based on interpolated feature matching.
نویسندگان
چکیده
Recently, digital stereo microscopes have been becoming increasingly popular in fields such as biomedicine and biotechnology. As such, being able to precisely match left/right feature pairs is critical, which is an important step in stereo matching. We hereby propose a dynamic interpolation method that combines two dimensional calibration and depth information to achieve stereo matching. In this experiment, we obtained the original scale-invariant feature transform feature point pairs and selected a pair of matching units. Based on the selected pair of matching elements and interpolated feature points shown in the left view of stereo microscope image, the dynamically interpolated feature points in the right view were developed to perform stereo measurements. The experimental results revealed that the proposed method can realize stereo microscopic measurements; results with high reliability can be achieved with a large quantity of matching elements.
منابع مشابه
Optimizing Disparity Candidates Space in Dense Stereo Matching
In this paper, a new approach for optimizing disparity candidates space is proposed for the solution of dense stereo matching problem. The main objectives of this approachare the reduction of average number of disparity candidates per pixel with low computational cost and high assurance of retaining the correct answer. These can be realized due to the effective use of multiple radial windows, i...
متن کاملطراحی و توسعه یک روش تلفیقی تناظریابی ناحیه ای و عارضه مبنای جدید برای توجیه نسبی در فتوگرامتری برد کوتاه
By far, many stereo-matching techniques have been successfully proposed and applied in digital aerial photogrammetry. However, due to some problems such as large parallaxes, occlusions, geometric deformations, and repetitive patterns in convergent close range images, these methods may not be applicable to the same level of success as that of aerial imagery. In order to overcome these shortcomin...
متن کاملNew Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor
Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...
متن کاملA similarity measure for stereo feature matching
An approach to stereo feature matching is presented with the introduction of a similarity measure for evaluating and confirming a stereo match. The contributions of this study are reflected in (1) the development of a similarity measure which evaluates a stereo match based on feature locality and gray-level gradient associated with the feature; and (2) the use of a matching procedure that integ...
متن کاملEffective Parameters in Search Space Reduction Used in a Fast Edge-based Stereo Matching
Reduction of search region in stereo correspondence can increase performances of the matching process, in the context of execution time and accuracy. For an edge-based stereo matching, we establish relationships between the search space and the parameters like relative displacement of edges, disparity under consideration, image resolution, CCD (Charge-Coupled Device) dimension and focal length ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bio-medical materials and engineering
دوره 26 Suppl 1 شماره
صفحات -
تاریخ انتشار 2015