Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous-wave Doppler velocity meter.
نویسندگان
چکیده
Peak aortic blood acceleration is recognized to be a sensitive index of global left ventricular performance. In the present study peak acceleration was assessed noninvasively in patients with a continuous-wave Doppler velocity meter. Peak aortic blood velocity and peak blood acceleration were measured by placing the ultrasonic transducer at the suprasternal notch. Measurements were obtained in 36 patients undergoing diagnostic cardiac catheterization. Peak velocity and acceleration were measured at rest just before left ventriculography. In patients with ejection fractions greater than 60%, peak acceleration was 19 +/- 5 m/sec/sec. In patients with ejection fractions of 41% to 60%, peak acceleration was lower, at 12 +/- 2 m/sec/sec (p less than .001). In patients with ejection fractions of 40% or less, peak acceleration (8 +/- 2 m/sec/sec) was markedly lower than in patients with ejection fractions greater than 60% (p less than .001). Peak acceleration showed a good linear correlation with ejection fraction (r = .90), and a better power fit (r = .93). These results indicate that peak acceleration, measured noninvasively with a continuous-wave Doppler velocity meter, is a useful indicator of global left ventricular performance.
منابع مشابه
VENTRICULAR PERFORMANCE Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous - wave Doppler velocity meter
Peak aortic blood acceleration is recognized to be a sensitive index of global left ventricular performance. In the present study peak acceleration was assessed noninvasively in patients with a continuous-wave Doppler velocity meter. Peak aortic blood velocity and peak blood acceleration were measured by placing the ultrasonic transducer at the suprastemal notch. Measurements were obtained in 3...
متن کاملVENTRICULAR PERFORMANCE Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous - wave Doppler velocity
Peak aortic blood acceleration is recognized to be a sensitive index of global left ventricular performance. In the present study peak acceleration was assessed noninvasively in patients with a continuous-wave Doppler velocity meter. Peak aortic blood velocity and peak blood acceleration were measured by placing the ultrasonic transducer at the suprastemal notch. Measurements were obtained in 3...
متن کاملThe influence of preload and heart rate on Doppler echocardiographic indexes of left ventricular performance: comparison with invasive indexes in an experimental preparation.
We evaluated the ability of Doppler echocardiography to assess left ventricular performance in six open-chest dogs studied under various conditions. Intravenous infusions of nitroglycerin were used to vary preload, atrial pacing was used to control heart rate, and changes in inotropic state were induced by two different doses of dobutamine (5 and 10 micrograms/kg/min iv) and by administration o...
متن کاملAORTIC REGURGITATION Noninvasive evaluation of aortic regurgitation by continuous - wave Doppler echocardiography
Continuous-wave Doppler echocardiography was used to examine the aortic regurgitant flow velocity pattern in 32 patients with aortic regurgitation (AR) and 10 patients without AR. The aortic regurgitant flow velocity patterns, characterized by a rapid rise in flow velocity immediately after closure of the aortic valve, high peak flow velocity, and a gradual deceleration until the next aortic va...
متن کاملLEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION
In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 74 2 شماره
صفحات -
تاریخ انتشار 1986