Experimental and numerical study of the propagation of a discharge in a capillary tube in air at atmospheric pressure
نویسندگان
چکیده
This paper presents an experimental and numerical study of a pulsed air plasma discharge at atmospheric pressure propagating in a capillary glass tube. In this work, we have compared the discharge structures and the axial propagation velocities of discharges. First, we have studied a needle-to-plane configuration without tube. For applied voltages in the range 7 − 18 kV, we have observed in experiments and in simulations that a plasma ball starts to develop around the needle tip. Then, for applied voltages less than 14 kV, in experiments, the discharge rapidly splits into several streamer channels with a main axial streamer. In simulations, we have computed only the main axial discharge. For applied voltages higher than 14 kV, in experiments and in simulations, we have observed that the discharge propagates with a cone shape in the gap. For all studied voltages, a good experiment/modeling agreement is obtained on the axial propagation velocity of the discharge, which increases with the applied voltage. Then, we have studied the propagation of discharges inside capillary tubes with radii in the range 37.5 − 300μm. In experiments and simulations, we have observed that for small tube radius, the discharge front is quite homogeneous inside the tube and becomes tubular when the tube radius increases. Experimentally, we have observed that the velocity of the discharge reaches a maximum for a tube radius slightly less than 100μm. We have noted that for a tube radius of 100μm, the discharge velocity is three to four times higher than the velocity obtained without tube. This clearly shows the influence of the confinement by a capillary tube on the discharge dynamics. In this work, we have only simulated discharges for tube radii in the range 100 − 300μm. We have noted that both in experiments and in simulations, the velocity of the discharge in tubes increases linearly with the applied voltage. As the radius of the tube decreases, the discharge velocity derived from the simulations slightly increases but is less than the experimental one. We have noted that the discrepancy on the discharge velocity between experiments and simulations increases as the voltage increases.
منابع مشابه
Numerical and experimental investigation of common rail fuel injection system and evaluating influence of fuel pressure on injection characteristics and pressure fluctuations
The combustion processes, engine performance, fuel consumption, exhaust-gas composition, and combustion noise in the diesel engine are closely linked to appropriate mixture of air-fuel in combustion chamber. The fuel-injection parameters such as injection start point, discharge rate curve, injection time and injection pressure are defined by the quality of the mixture formation. The numerical m...
متن کاملAnalytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Aluminum Tube Joints
Electromagnetic forming is a high energy rate forming process in which an electromagnetic Lorentz body force is used for deformation of products. In this article, electromagnetic forming process was simulated for the assembly of parts as an innovative method. The effect of important process parameters such as discharge energy, radius and width of rectangular groove on the strength of the asse...
متن کاملAnalytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Aluminum Tube Joints
Electromagnetic forming is a high energy rate forming process in which an electromagnetic Lorentz body force is used for deformation of products. In this article, electromagnetic forming process was simulated for the assembly of parts as an innovative method. The effect of important process parameters such as discharge energy, radius and width of rectangular groove on the strength of the asse...
متن کاملTwo Phase Heat Transfer Characteristics in a Vertical Small Diameter Tube at Sub Atmospheric Pressure
Two-phase heat transfer is experimentally examined through vertical small diameter tubes, D =1.45 and 2.8 mm using water under a pressure of 50 to 81 kPa and a natural circulation condition. The pool boiling correlation by Stephan-Abdelsalam and the thermosyphon boiling correlation by Imura, et al. predict the measured experimental data in the 2.8 mm tube with an error of -30%. A large heat tra...
متن کاملAnalytical and Numerical Investigation of Significant Parameters on Strength of Electromagnetically Assembled Products Joints
Electromagnetic forming is a high energy rate forming process. In this process, an electromagnetic Lorentz body force is used for deformation of products. In this article, Electromagnetic forming process was simulated for assembly of parts as an innovative method. In this research work, the effect of important parameters of process such as discharge energy, radius and width of rectangular groov...
متن کامل