Comparison of measurement of pupil sizes among the colvard pupillometer, procyon pupillometer, and NIDEK OPD-scan.
نویسندگان
چکیده
PURPOSE To compare pupil sizes measured with the Colvard pupillometer, Procyon pupillometer, and NIDEK OPD-Scan. METHODS Pupil diameter was measured in 90 consecutive eyes from 55 patients under mesopic and scotopic light conditions with all three instruments. RESULTS The mean scotopic pupil diameter was 6.3+/-0.98 mm with the Colvard pupillometer and 6.45+/-1.01 mm with the Procyon pupillometer. The mean mesopic pupillometer was 5.58+/-1.01 mm with the Procyon pupillometer and 6.26-0.99 mm with the CONCLUSIONS The mesopic pupil diameter measured with the NIDEK OPD-Scan is more consistent with the scotopic pupil diameter measured with the Procyon and Colvard pupillometers than the mesopic pupil diameter measured with the Procyon pupillometer.
منابع مشابه
Comparison of the Colvard, Procyon, and Neuroptics pupillometers for measuring pupil diameter under low ambient illumination.
PURPOSE To compare three different pupillometers (Colvard, Procyon, and Neuroptics) for determining pupil diameter at 0.04 and 0.4 lux ambient illumination. METHODS In 92 eyes of 46 healthy volunteers, pupil diameter was measured at 0.04 and 0.4 lux. After dark adaptation for 2 minutes, measurements were performed with each device by two examiners. Interobserver agreement, instrument agreemen...
متن کاملPre-excimer laser and post-excimer laser refractive surgery measurements of scotopic pupil diameter using 2 pupillometers.
PURPOSE To compare a digital infrared pupillometer with a handheld light amplification pupillometer for measuring scotopic pupil size and to evaluate if the postoperative refractive changes of the cornea can influence pupil measurements. DESIGN Prospective noncomparative interventional case series. PARTICIPANTS One hundred eyes, 50 myopic (mean spherical equivalent [SE] refraction [+/- stan...
متن کاملColvard pupillometer measurement of scotopic pupil diameter in emmetropes and myopes.
PURPOSE To prospectively compare the scotopic pupil size between emmetropes and myopes using a Colvard pupillometer. METHODS The pupil diameters of 55 normal subjects and 55 healthy myopic subjects were measured with the Colvard pupillometer in a low-light situation that simulated the level of light encountered while driving at night. RESULTS The mean (+/- SD) age of the emmetropic subjects...
متن کاملEvaluation of pupil dynamics after implantation of artisan phakic intraocular lenses.
PURPOSE To compare pre- and postoperative horizontal and vertical pupil diameters after horizontal Artisan phakic intraocular lens (PIOL) (Ophtec BV, Groningen, The Netherlands) implantation for correction of myopia. METHODS The pre- and postoperative scotopic pupil diameters measured by the Colvard pupillometer (Oasis Medical, Glendora, Calif) were compared in 71 eyes after Artisan PIOL impl...
متن کاملPupillometric Assessment of Autonomic Nervous System in Children with Allergic Rhinitis
OBJECTIVE The purpose of this study was to investigate autonomic nervous system dysfunction by measuring pupil sizes in pediatric patients with allergic rhinitis. SUBJECTS AND METHODS The study group consisted of 60 children (28 girls and 32 boys) who were age and gender matched with the control group, which also consisted of 60 children (26 girls and 34 boys). The diagnosis of allergic rhini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 22 9 Suppl شماره
صفحات -
تاریخ انتشار 2006