Quantitative study on exact reconstruction sampling condition by verifying solution uniqueness in limited-view CT.

نویسندگان

  • Bin Yan
  • Wenkun Zhang
  • Lei Li
  • Hanming Zhang
  • Linyuan Wang
چکیده

In limited-view computed tomography reconstruction, iterative image reconstruction with sparsity-exploiting methods, such as total variation (TV) minimization, inspired by compressive sensing, potentially claims large reductions in sampling requirements. However, a quantitative notion of this claim is non-trivial because of the ill-defined reduction in sampling achieved by the sparsity-exploiting method. In this paper, exact reconstruction sampling condition for limited-view problem is studied by verifying the uniqueness of solution in TV minimization model. Uniqueness is tested by solving a convex optimization problem derived from the sufficient and necessary condition of solution uniqueness. Through this method, the sufficient sampling number of exact reconstruction is quantified for any fixed phantom and settled geometrical parameter in the limited-view problem. This paper provides a reference to quantify the sampling condition. Three phantoms are tested to study the sampling condition of limited view exact reconstruction in this paper. The experiment results show the quantified sampling number and indicate that an object would be accurately reconstructed as the scanning range becomes narrower by increasing sampling number. The increased samplings compensate for the deficiency of the projection angle. However, the lower bound of the scanning range corresponding to three different phantoms are presented, in which an exact reconstruction cannot be obtained once the projection angular is narrowed to this extent no matter how to increase sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testable uniqueness conditions for empirical assessment of undersampling levels in total variation-regularized x-ray CT

We study recoverability in fan-beam computed tomography (CT) with sparsity and total variation priors: how many underdetermined linear measurements suffice for recovering images of given sparsity? Results from compressed sensing (CS) establish such conditions for, e.g., random measurements, but not for CT. Recoverability is typically tested by checking whether a computed solution recovers the o...

متن کامل

Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch.

The goal of this paper is to study Cone-beam CT scanning along a helix of variable pitch. First the rationale and applications in medical imaging of variable pitch CT reconstruction are explained. Then formulas for the minimum detection window are derived. The main part of the paper proves a necessary and sufficient condition for the existence and uniqueness of PI-lines inside this variable pit...

متن کامل

Tomographic Image Reconstruction in Noisy and Limited Data Settings

Reconstruction of images from projections lays the foundations for computed tomography (CT). Tomographic image reconstruction, due to its numerous real world applications, from medical scanners in radiology and nuclear medicine to industrial scanning and seismic equipment, is an extensively studied problem. The study of reconstructing function from its projections/line integrals, is around a ce...

متن کامل

Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image Reconstruction

In computed tomography (CT), there are many situations where reconstruction has to be performed with sparse-view data. In sparse-view CT imaging, strong streak artifacts may appear in conventionally reconstructed images due to limited sampling rate that compromises image quality. Compressed sensing (CS) algorithm has shown potential to accurately recover images from highly undersampled data. In...

متن کامل

Improved total variation minimization method for few-view computed tomography image reconstruction

BACKGROUND Due to the harmful radiation dose effects for patients, minimizing the x-ray exposure risk has been an area of active research in medical computed tomography (CT) imaging. In CT, reducing the number of projection views is an effective means for reducing dose. The use of fewer projection views can also lead to a reduced imaging time and minimizing potential motion artifacts. However, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 2016