OBJECTIVE Significant dilation of the pulmonary autograft is problematic after the Ross operation and may require reoperation. Pulmonary autograft remodelling occurs in response to the immediate rise in pressure and consequently wall stress. Stress-strain response of the pulmonary root plays an important role in understanding autograft function and remodelling following the Ross procedure. However, limited data are available on mechanical properties of fresh human pulmonary roots. The aim of this study was to compare mechanical properties of fresh human pulmonary and aortic roots prior to the Ross operation. METHODS Fresh healthy human hearts (n = 21) were obtained from California Transplant Donor Network (Oakland, CA, USA). Five regions of pulmonary and aortic roots, anterior and posterior artery and three sinuses, were subjected to displacement-controlled equibiaxial stretch testing within 24 h of cross-clamp time. Different regions of pulmonary and aortic roots were compared using a paired-comparison approach based on tissue stiffness at systemic pressure. Furthermore, histologic analysis was performed to compare the fibrous structure of pulmonary and aortic roots. RESULTS Human pulmonary and aortic roots demonstrated nonlinear response to biaxial loading in both circumferential and longitudinal directions. Pulmonary artery was found to be significantly stiffer than ascending aorta at systemic pressure in the two principal directions (P < 0.001). Similarly, pulmonary sinuses were significantly stiffer than the aortic sinuses at systemic pressure in the two directions (P < 0.001). Histological analysis revealed that aortic roots had tight denser weave of elastin than pulmonary roots. CONCLUSIONS Significant differences were found in the compliance and fibrous structure of human pulmonary and aortic roots. These regional differences may impact pulmonary autograft remodelling and influence late autograft dilation.
منابع مشابه
Biomechanics of the pulmonary autograft valve in the aortic position.
Pulmonary autograft valve replacement has been simulated by implanting the pulmonary valve into the aortic position of the same cadaver heart from both human and porcine sources. The forces acting on the pulmonary valve leaflets have been calculated on the basis of a triaxial ellipsoid mathematical model. These forces on the pulmonary autograft valve were shown to be essentially similar to thos...
متن کاملGeometric models of the aortic and pulmonary roots: suggestions for the Ross procedure.
OBJECTIVE To discuss geometric factors, which may influence long-term results relating to homograft competence following the Ross procedure, we describe the 3D morphology of the pulmonary and aortic roots. MATERIALS Measurements were made on 25 human aortic and pulmonary roots. Inter-commissural distances and the heights of the sinuses were measured. For geometrical reconstruction the three c...
متن کاملتعویض دریچه آئورت: مقایسه روش متداول و روش جدید
Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...
متن کاملStudy of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...
متن کاملIn-vitro study on the relationship between progressive sinotubular junction dilatation and aortic regurgitation for several stentless aortic valve substitutes.
OBJECTIVE Stentless aortic valves are widely used due to their excellent hemodynamic properties. However, if the subcoronary implantation technique is used later dilatation of the sinotubular junction (STJ) can cause regurgitation. The aim of the study was to determine the dilatation tolerance of two commercially available stentless xenografts and fresh aortic and pulmonary roots against such d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2012