Accuracy of forced oscillation technique to assess lung function in geriatric COPD population
نویسندگان
چکیده
INTRODUCTION Performing lung function test in geriatric patients has never been an easy task. With well-established evidence indicating impaired small airway function and air trapping in patients with geriatric COPD, utilizing forced oscillation technique (FOT) as a supplementary tool may aid in the assessment of lung function in this population. AIMS To study the use of FOT in the assessment of airflow limitation and air trapping in geriatric COPD patients. STUDY DESIGN A cross-sectional study in a public hospital in Hong Kong. ClinicalTrials.gov ID: NCT01553812. METHODS Geriatric patients who had spirometry-diagnosed COPD were recruited, with both FOT and plethysmography performed. "Resistance" and "reactance" FOT parameters were compared to plethysmography for the assessment of air trapping and airflow limitation. RESULTS In total, 158 COPD subjects with a mean age of 71.9±0.7 years and percentage of forced expiratory volume in 1 second of 53.4±1.7 L were recruited. FOT values had a good correlation (r=0.4-0.7) to spirometric data. In general, X values (reactance) were better than R values (resistance), showing a higher correlation with spirometric data in airflow limitation (r=0.07-0.49 vs 0.61-0.67), small airway (r=0.05-0.48 vs 0.56-0.65), and lung volume (r=0.12-0.29 vs 0.43-0.49). In addition, resonance frequency (Fres) and frequency dependence (FDep) could well identify the severe type (percentage of forced expiratory volume in 1 second <50%) of COPD with high sensitivity (0.76, 0.71) and specificity (0.72, 0.64) (area under the curve: 0.8 and 0.77, respectively). Moreover, X values could stratify different severities of air trapping, while R values could not. CONCLUSION FOT may act as a simple and accurate tool in the assessment of severity of airflow limitation, small and central airway function, and air trapping in patients with geriatric COPD who have difficulties performing conventional lung function test. Moreover, reactance parameters were better than resistance parameters in correlation with air trapping.
منابع مشابه
The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test
Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...
متن کاملImpact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study
BACKGROUND Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of ...
متن کاملRespiratory impedance is correlated with morphological changes in the lungs on three-dimensional CT in patients with COPD
The forced oscillation technique provides information concerning respiratory impedance, which comprises resistance and reactance of the respiratory system. However, its relationship with morphological changes of the lungs in chronic obstructive pulmonary disease (COPD) remains unclear. Respiratory impedance and spirometric data were evaluated in 98 patients with COPD and 49 reference subjects. ...
متن کاملVariability of within-breath reactance in COPD patients and its association with dyspnoea.
The forced oscillation technique can identify expiratory flow limitation (EFL) when a large difference in inspiratory and expiratory reactance (ΔXrs) occurs. However, flow limitation can vary from breath to breath, and so we compared a multiple-breath ΔXrs approach to the traditional breath-by-breath assessment of EFL. We investigated the within- and between-day reproducibility and the factors ...
متن کاملThe relationship between different diet quality indices and severity of airflow obstruction among COPD patients
Background: Chronic obstructive pulmonary disease (COPD) is a major public health problem worldwide. Smoking is the number one cause of COPD; however, genetic, environmental and dietary factors contribute to the etiology of this disease. In this study, we assessed the association between three diet quality indices -the Healthy Eating Index-2005 (HEI-2005), the Healthy Eating Index-2010 (HEI-201...
متن کامل