SU-E-T-592: Comparison of Low Dose Volume and Integral Dose in Rotational Arc Radiation Therapy Modalities.

نویسندگان

  • J Lian
  • H Song
  • R Liu
  • S Qi
  • A Hu
چکیده

PURPOSE To compare low dose volume and integral dose of various rotational arc radiation therapy modalities, including helical tomotherapy (HT) and other volumetric modulated arc therapies (VMAT). METHODS A digital cylindrical phantom and an anthropomorphic pelvic phantom were used in the study. HT treatment was planned on TomoTherapy Planning Station (Accuray) and VMAT plans were generated on Pinnacle (Philips) and Eclipse (Varian). Same objectives and criteria were used for all the planning tasks. Tomotherapy plans were made with both 1cm jaw and 2.5cm jaw. Pinnacle SmartArc and Eclipse RapidArc plans used 1 arc and 2 arcs. Plan quality was evaluated by dose-volume histograms, conformity index (CI), and heterogeneity index (HI). V10% and V20% of body were used in quantifying low dose volume. Integral doses were computed for each plan and compared. Dose profiles across the target center were retrieved to show the rate of dose falls off. RESULTS All arc TPS generated clinically acceptable plan with comparable target CI and HI. The V20% of body of the cylindrical phantom case were 3551cc, 4054cc, 3375cc, 3438cc, 3714cc and 3679cc for tomotherapy 1 cm and 2 cm jaw, SmartArc 1 arc and 2 arc, and RapidArc 1 arc and 2 arc plans, respectively. The integral doses were 19.67, 22.78, 18.68, 18.50, 19.78 and 19.73 Joule, respectively. For the anthropomorphic phantom, the integral doses were 81.69, 102.77, 84.5 and 82.5 Joule for tomotherapy 1cm, 2cm, SmartArc 1arc and RapidArc 1arc, respectively. Dose profiles showed tomotherapy 1cm plan had similar longitudinal penumbra as SmartArc and RapidArc, while tomotherapy 2.5cm plan produced significant broader penumbra. CONCLUSIONS Similar low dose volume and integral dose are found in SmartArc, Rapid Arc, and as well as helical tomotherapy plan of 1cm jaw. Tomotherapy plans of 2.5cm jaw, however, shows higher low dose volume and integral dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

متن کامل

Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, SmartarcTM, and 3D Conventional Radiation Therapy

Purpose: Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison was performed between tomotherapy, volumetric modulated arc therapy (VMAT), and 3D conformal radiation therapy (3D-CRT) for CSI. Methods and Materials: Five (n = 5) CSI patients were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part19  شماره 

صفحات  -

تاریخ انتشار 2012