Effect of citrate on plasma aluminium concentration and aluminium excretion in the rat.
نویسندگان
چکیده
1. Plasma aluminium concentration and urinary aluminium excretion were monitored for 4.5 h in rats after the administration of 25 micrograms or 800 micrograms of aluminium as an intravenous bolus, either as aluminium chloride or as aluminium citrate (i.e. aluminium chloride together with sodium citrate). 2. Immediately after the bolus aluminium administration, the plasma aluminium concentration was higher in the groups given aluminium chloride than in those which received aluminium citrate, although the difference was significant (P < 0.05) only for the 25 micrograms dose. This difference between aluminium chloride and citrate indicates that the citrate form has a higher volume of distribution (i.e. is able to leave the plasma). The calculated volume of distribution for the 25 micrograms of aluminium chloride (17.5 ml) was similar to the plasma volume of the rats used (15 ml). 3. In experiments in vitro, the ultrafilterability of aqueous solutions of aluminium chloride and aluminium citrate were compared. Only 1.05 +/- 0.09% of the aluminium chloride solution was ultrafilterable (aluminium concentration 28,200 +/- 730 ng/ml), whereas 97.3 +/- 2.4% of the aluminium citrate was ultrafilterable (aluminium concentration 42,000 +/- 370 ng/ml). When the filterability of aluminium in plasma was examined, the aluminium chloride ultrafilterability was identical with that in aqueous solution (1.06 +/- 0.13%, aluminium concentration 19,800 +/- 2956 ng/ml), but the aluminium citrate was 79.8 +/- 7.1% ultrafilterable (aluminium concentration 10,125 +/- 591 ng/ml).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
INTERFERENCE OF ALUMINIUM WITH CARBOHYDRATE METABOLISM IN MALE RATS: A MODEL STUDY OF DIALYSIS PATIENTS
The effects of aluminium and aluminium-citrate on some serum parameters related to carbohydrate metabolism in male Wistar rats were investigated. Daily intraperitoneal administrations of 1 mg/kg body weight of aluminium or aluminiumcitrate (1: 1) for 50 days led to the elevation of serum insulin by 24 or 40 percent respectively, with the concomitant decrease in serum glucose concentrations ...
متن کاملContribution of soluble aluminium species to absorption of aluminium from the rat gut in situ.
1. Rat gut perfusion studies in vivo at pH 4, 6 or 8 using aluminium chloride or equimolar aluminium chloride and sodium citrate showed that elevated plasma aluminium concentrations were associated with aluminium solubility in the perfusion. Elevated plasma aluminium levels and soluble aluminium in the perfusate occurred with perfusion of equimolar aluminium chloride and sodium citrate at all t...
متن کاملIntestinal absorption of trace amounts of aluminium in rats studied with 26aluminium and accelerator mass spectrometry.
1. Until recently studies of intestinal aluminium absorption used pharmacological amounts of stable 27Al. 2. To examine the intestinal absorption of trace amounts of different chemical compounds of aluminium, in the present study we have employed the long half-life isotope of aluminium, 26Al, and accelerator mass spectrometry. Trace amounts of 26Al (2.7-12.1 ng) as the hydroxide, citrate, citra...
متن کاملDetermintion of the acute and persistant effects of Aluminium on memory and learning Abilities of rat
In regard to the role of Aluminium in the emergence of psychological disorded in patients with chronic kidney diseases,this research project studied the acute,and chronic effects of Alluminium on different stages of memory and learning abilitis,after grouping the rats Alluminium chloride with concentrations of 1mg,5mg,10mg and 20 mg was used per kg of body weight.the Alluminium was given by int...
متن کاملSTUDY ON CORROSION PROPERTIES OF PLASMA NITRIDED PURE ALUMINIUM
Abstract: In this research plasma nitriding of pure aluminium and effect of iron elemental alloy on the formation and growth of aluminium nitride was investigated. Also corrosion properties of formed AlN were investigated. After preparation, the samples were plasma nitrided at 550oC, for 6, 9 and 12 h and a gas mixture of 25%H2-75%N2. The microstructure and phases analysis were investigated usi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 83 4 شماره
صفحات -
تاریخ انتشار 1992