The Air-Conditioning Energy Savings Achieved by Application of Time- Predicted Driven Night Ventilation

نویسندگان

  • Maja Todorovic
  • Maja Todorović
چکیده

This paper analyses the influence of time-predicted night ventilation applied during the summer season on the total energy consumption of airconditioning system. Analysis has been made on the basis of a computer program for dynamic simulation of air-conditioned rooms thermal behavior. The program was developed at the Department for Thermal Engineering at the Faculty of Mechanical Engineering, University of Belgrade. Air-conditioning operating modes without and with application of night ventilation, and different periods of night ventilation are analysed. Cooling loads, fan energy consumption and overall energy consumption for summer conditions for Belgrade for the whole cooling season are given. The obtained results were compared, and hereupon a review is given of the energy savings for the whole cooling season.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing naturally driven air flow in a vertical pipe by changing the intensity and location of the wall heat flux

Heat transfer from the internal surfaces of a vertical pipe to the adjacent air gives rise to the air flow establishment within the pipe. With the aim of optimizing the convective air flow rate in a vertical pipe, the details of the flow and thermal fields were investigated in the present study. Conservation equations of mass, momentum, and energy were solved numerically using simple implicit f...

متن کامل

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems

The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy c...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Residential Ventilation and Energy Characteristics *

The role of ventilation in the housing stock is to provide fresh air and to dilute internally-generated pollutants in order to assure adequate indoor air quality. Energy is required to provide this ventilation service, either directly for moving the air or indirectly for conditioning the outdoor air for thermal comfort. Different kinds of ventilation systems have different energy requirements. ...