Improving the Protection of Ehv Teed Feeders Using Local Agents
نویسندگان
چکیده
The protection of multi-terminal lines is not as simple as that of two-terminal lines. They usually experience additional problems caused by the intermediate infeed from the third terminal, an outfeed, different line lengths to the tee point, etc. The limitations of non-pilot distance relays for their protection have been acknowledged for decades. These limitations lead to the traditional distance relaying approach to experience severe underreach and overreach problems. The relay first zone reach may not even extend beyond the tee point in some underreach cases (1),(2). An approach based on adaptive relaying to face such a situation and some fundamental concepts concerning it was presented by Rockefeller (3). Horowitz et al (4) define adaptive relaying as a protection philosophy which permits and seeks to make adjustments to various protection functions in order to make them more attuned to prevailing power system conditions. An adaptive setting concept for two and three terminal lines, which can respond to changes in the network conditions, was proposed by Xia et al (5), (6). Stedall et al (7) also proposed an investigation into the use of adaptive setting techniques for improved distance back-up protection. This paper discusses the adaptation of the settings of distance relays for multi-terminal lines employing agents. Agents are software processes capable of searching for information in networks, interacting with pieces of equipment and performing tasks on behalf of their owners (relays). Moreover, they are autonomous and cooperative. Very few publications concerning the application of agents in the protection field have been reported in the literature. Tomita et al (8) proposed a cooperative protection system utilizing agents. Relay agents were constructed, and the cooperation of the main agents was simulated for primary, backup and adaptive protection. Results illustrating the improved performance of the adaptive method proposed compared to conventional fixed settings are presented in the following sections.
منابع مشابه
Lightning Protection of Ehv Substations in Iran
Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.
متن کاملEquine herpes virus type 1 (EHV-1) and 4 (EHV-4) infections in horses and donkeys in northeastern Turkey
The herpesviruses infections in equides are caused by five different serotypes of viruses, belonging to family Herpesviridae. The goal of this study was to conduct a seroepidemiological investigation of equine herpesvirus type 1 (EHV-1) and type 4 (EHV-4) in horses and donkeys raised in two provinces and their villages in northeastern Turkey. A total of 666 samples from 423 horses and 243 donke...
متن کاملExperimental Study for Protection of Piers Against Local Scour Using Slots
The most important causes of bridge failure are local scour. In this study, laboratory experiments were conducted to investigate the effectiveness of slot as a protection device in reduction of depth of scour at cylindrical piers under clear water flow conditions. The development time of scour depth at the circular pier with and without a slot as a protection device was conducted. The experimen...
متن کاملA local measurement-based protection scheme for DER integrated DC microgrid using Bagging Tree
In recent years, DC microgrid has attracted considerable attention of the research community because of the wide usage of DC power-based appliances. However, the acceptance of DC microgrid by power utilities is still limited due to the issues associated with the development of a reliable protection scheme. The high magnitude of DC fault current, its rapid rate of rising and absence of zero cros...
متن کاملThe Effects of the Reverse Current Caused by the Series Compensation on the Current Differential Protection
The series capacitor compensation is one of the key technologies in the EHV and UHV long distance power transmission lines. This paper analyzes the operation characteristics of the main protection combined with the engineering practice when the transmission line overcompensation due to the series compensation system is modified and analyzes the influence of the transition resistance and the sys...
متن کامل