Speeding-up MR acquisitions using ultrasound signals, and scanner-less real-time MR imaging

نویسندگان

  • Frank Preiswerk
  • W. Scott Hoge
  • Matthew Toews
  • Jr-yuan George Chiou
  • Laurent Chauvin
  • Lawrence P. Panych
  • Bruno Madore
چکیده

Target Audience: Researchers and clinicians interested in real-time MRI and image-guided therapies. Purpose: MRI and ultrasound (US) imaging have complementary properties and advantages, with great soft tissue contrast for the former and high acquisition rates for the latter. For this reason several noteworthy efforts have been made to combine the two imaging modalities. A characteristic of the approach pursued here is that the US transducer is very simple: The small 8mm-diameter single-element probe is held in place using an adhesive bandage (Fig. 1), and a flexible MR coil array can simply be wrapped over it. The emitted US field is not focused, it is expected to penetrate and reflect possibly several times within the abdomen, and the received signal acts as a unique signature of the internal organ arrangement at any given moment. While there is nothing special about the US transducer itself, or the MR images being acquired, interesting behaviors emerge when detecting correlations between raw US signals and the MR images. After a training period extending roughly a few breathing cycles the US signal can become a surrogate for the MR imaging system. The US signal can be used to generate extra MR images in-between actually-acquired ones, to boost temporal resolution. Alternately, synthetic MR images can be generated even after the volunteer has been physically removed from the MR scanner, based solely on incoming US signals and previously-learned correlations between the two modalities. This intriguing ‘scanner-less real-time MRI’ behavior might, in principle at least, allow image-guided procedures to be performed outside the confines of the imaging bore. Methods: Five volunteers were imaged with the hybrid US+MR setup, following informed consent. Fiberoptic probes monitored the temperature of the transducer and its cable, and scanning would have been stopped if either had exceeded body temperature (threshold at 38C). The US transducer (Imasonic, 8mm, 5.8MHz) was held to the volunteer’s abdomen using an adhesive bandage, and a product 8-channel cardiac array was wrapped over it. The first 4 subjects were imaged using a single-slice acquisition (5mm-thick sagittal, 30 flip angle, FOV between 20 and 24cm, matrix size 128×96 or 128×128, TR between 7 and 15ms, MR temporal resolution between 0.48 and 1.15s, US frame rate = 1/TR, i.e., from 56 to 156Hz). The last subject was scanned instead with a 2-plane scheme (5mm slices, 30 flip angle, FOV=38cm, 192×192, TR=18ms, 75% partial-Fourier, two-fold parallel imaging, 0.58s per MR image, US frame rate = 56Hz). For every incoming US trace , the -nearest (most similar) past traces were matched using Pearson’s correlation coefficient. The images associated with these traces were averaged, yielding a synthetic MR image for the present time point. The boost in temporal resolution provided by the algorithm was enormous, from about 20to 100-fold in the datasets reconstructed here. Frame rates above 20-30Hz are beyond the abilities of human eyes, and so averaging was performed to bring frame rates down to ~25Hz. A sliding window was used to average previous estimations, see right term in Eq. 1, with 1. The number of selected nearest matches, , is adjusted depending on their correlation score. The maximum number is , and a smaller number gets used instead if there is a paucity of good matches. This situation may happen, for example, at the beginning of an exam when few time frames are available, or when rarely-seen motion such as especiallydeep inspirations occur. In such cases when a small number of good matches are available, is kept small, and weight on the second term in Eq. 1, , is increased. This is formulated as a linear program argmax , ... , subject to the conditions |max min | and , where c is the vector of correlation scores of the best matches, is the sliding-window standard deviation of the past averages of c and is a weight factor. Upon determination of , the weights in Eq. 1 are set to / and 1 . The result is a flexible algorithm that adapts to the statistics of the ultrasound data stream: If the number of high-quality matches is low, the algorithm puts less trust in them and emphasizes the previous frames instead. Results: The algorithm was applied to all acquired slices, including those of the sagittal-coronal scheme. As time progresses, the database of previously sampled data grows and with it the quality of synthetic MR images. Two 5s representative time segments are shown in Fig. 3 using an M-mode format. The superior-inferior motion of one image line through the liver gives rise to an oscillatory pattern in Fig. 3 during breathing. For the earlier segment on the left, note that motion appears much more natural and smooth for the 56Hz synthetic MR data than the 1.7Hz acquired MR data. For the later segment on the right, the MR stream of data had ended, yet synthetic MR images may still be generated based solely on the US signal. Parameters 7, 3 7, 100 400, 3 were employed here. Discussion and Conclusion: Our algorithm produces an MR image stream with high temporal resolution after a learning phase of simultaneous MRI+US acquisitions, even after the subject is taken out of the scanner. While the results presented here were obtained offline, a real-time framework for MRI+US imaging and prediction is currently being developed, as shown in Fig. 4, based on 3D Slicer and OpenIGTLink. References: [1] Arvanitis CD et al. Phys Med Biol 2013;58(14):4749-61. [2] Petrusca L et al. Invest Radiol 2013;48(5):333-40. [3] Gunther M, Feinberg DA. MRM 2004;52(1):27-32. [4] Feinberg DA et al. MRM 2010;63(2):290-6. [5] Schwartz BM et al. MRM 2013;69(4):1023-33. [6] Toews M et al. ISMRM 2013:0478. [7] Kording F et al. ISMRM 2013:1421. [8] Slicer3d, http://www.slicer.org. Support from NIH grants P41EB015898, R01EB010195 and R01CA149342 is acknowledged. Fig. 4: Overview of the real-time system being developed, whereby both streams of information are sampled, processed and fed into 3D Slicer for display. Fig. 1: An 8-mm MR-compatible US transducer (a) is placed in a holder along with fiber-optic temperature probes, and kept in place using an adhesive bandage (b). (a) (b)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid ultrasound MRI for improved cardiac imaging and real-time respiration control.

A hybridized dual-imaging system combining real-time ultrasound imaging and MRI was utilized for cardiac imaging at 1.5 T and 3 T. The ultrasound scanner with a programmable software interface was connected via computer to the MRI scanner. Electronic noise was eliminated with electromagnetic shielding and grounding to the screen room. At 3 T, real-time prospective motion compensation in dynamic...

متن کامل

Hybrid Utrasound and MRI Acquisitions for High-Speed Imaging of Respiratory Organ Motion

Magnetic Resonance (MR) imaging provides excellent image quality at a high cost and low frame rate. Ultrasound (US) provides poor image quality at a low cost and high frame rate. We propose an instance-based learning system to obtain the best of both worlds: high quality MR images at high frame rates from a low cost single-element US sensor. Concurrent US and MRI pairs are acquired during a rel...

متن کامل

MR-guided interventions for prostate cancer.

MR imaging is currently the most effective diagnostic imaging tool for visualizing the anatomy and pathology of the prostate gland. Currently, the practicality and cost effectiveness of transrectal ultrasound dominates image guidance for needle-based prostate interventions. Challenges to the integration of diagnostic and interventional MR imaging have included the lack of real-time feed-back, t...

متن کامل

MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU

BACKGROUND The availability of open and versatile software tools is a key feature to facilitate pre-clinical research for magnetic resonance imaging (MRI) and magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) and expedite clinical translation of diagnostic and therapeutic medical applications. In the present study, two customizable software tools that were developed at the T...

متن کامل

Real-time RF pulse adjustment for B0 drift correction.

Although the magnetic field of an MR scanner is very stable under little or no load, it can become less stable under heavy-duty cycle conditions, such as in diffusion tensor imaging (DTI). Uncorrected, such field drifts lead to an apparent image shift along the phase-encoding direction and decreasing effectiveness of fat saturation pulses. A method is presented to adjust the center frequency of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014