Ratiometry of transmembrane voltage-sensitive fluorescent dye emission in hearts.

نویسندگان

  • S B Knisley
  • R K Justice
  • W Kong
  • P L Johnson
چکیده

Transmembrane voltage-sensitive fluorescence measurements are limited by baseline drift that can obscure changes in resting membrane potential and by motion artifacts that can obscure repolarization. Voltage-dependent shift of emission wavelengths may allow reduction of drift and motion artifacts by emission ratiometry. We have tested this for action potentials and potassium-induced changes in resting membrane potential in rabbit hearts stained with di-4-ANEPPS [Pyridinium, 4-(2-(6-(dibutylamino)-2-naphthalenyl) ethenyl)-1-(3-sulfopropyl)-, hydroxide, inner salt] using laser excitation (488 nm) and a two-photomultiplier tube system or spectrofluorometer (resolution of 500-1,000 Hz and <1 mm). Green and red emissions produced upright and inverted action potentials, respectively. Ratios of green emission to red emission followed action potential contours and exhibited larger fractional changes than either emission alone (P < 0.001). The largest changes and signal-to-noise ratio (signal/noise) were obtained with numerator wavelengths of 525-550 nm and denominator wavelengths of 650-700 nm. Ratiometry lessened drift 56-66% (P < 0.015) and indicated decreases in resting membrane potential. Ratiometry lessened motion artifacts and increased magnitudes of deflections representing phase-zero depolarizations relative to total deflections by 123-188% in intact hearts (P < 0.02). Durations of action potentials at different pacing rates, temperatures, and potassium concentrations were independent of whether they were measured ratiometrically or with microelectrodes (P > or = 0.65). The ratiometric calibration slope was 0.017/100 mV and decreased with time. Thus emission ratiometry lessens the effects of motion and drift and indicates resting membrane potential changes and repolarization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts.

Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the ...

متن کامل

A near-infrared fluorescent voltage-sensitive dye allows for moderate-throughput electrophysiological analyses of human induced pluripotent stem cell-derived cardiomyocytes.

Human induced pluripotent stem cell-derived cardiomyocyte (iPSC-CM)-based assays are emerging as a promising tool for the in vitro preclinical screening of QT interval-prolonging side effects of drugs in development. A major impediment to the widespread use of human iPSC-CM assays is the low throughput of the currently available electrophysiological tools. To test the precision and applicabilit...

متن کامل

Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.

Motion artefact (MA) in voltage-sensitive fluorescent signals causes significant debasement of action potential. During ischemia and reperfusion in isolated rabbit heart, this artefact develops in a manner which may be described by the time of its onset, level, and shape. The MA during ischemia: (a) may become substantial with approximately two minutes delay after establishing global ischemia; ...

متن کامل

Fluorescence incoherent color holography.

We present a new imaging method to record multicolor digital holograms from objects emitting fluorescent light. The fluorescent light specific to the emission wavelength of various fluorescent dyes after excitation of three dimensional (3D) objects is recorded on a digital monochrome camera after reflection from a diffractive optical element (DOE). For each wavelength of fluorescent emission, t...

متن کامل

Voltage-Sensitive Fluorescence of Indocyanine Green in the Heart.

So far, the optical mapping of cardiac electrical signals using voltage-sensitive fluorescent dyes has only been performed in experimental studies because these dyes are not yet approved for clinical use. It was recently reported that the well-known and widely used fluorescent dye indocyanine green (ICG), which has FDA approval, exhibits voltage sensitivity in various tissues, thus raising hope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 279 3  شماره 

صفحات  -

تاریخ انتشار 2000