The Ringloc liner compared with the Hexloc liner in total hip arthroplasty

نویسندگان

  • Sköldenberg Olof
  • Salemyr Mats
  • Muren Olle
  • Johansson Åke
  • Ahl Torbjörn
  • Bodén Henrik
چکیده

The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc and 166 Ringloc) on 281 patients in the study. Revisions of prosthesis components were recorded and pelvic osteolytic lesions were assessed using radiographs and computed tomography. The linear head penetration rate was measured using the Martell method. The 10-year survival rate of the liner with revision due to liner wear and/or osteolysis as endpoint was 88% for the Hexloc liner and 98% for the Ringloc liner. The 15-year survival rate of the Hexloc liner was 67%. Pelvic osteolysis was found in 27% of the Hexloc and 19% of the Ringloc hips. After 15 years, 53% of the Hexloc hips had developed an osteolytic lesion. The linear head penetration rate was 0.16 mm/year for the Hexloc liner and 0.12 mm/year for the Ringloc liner. This paper is the first to describe the rapidly deteriorating survival up to 15 years with the old generation gamma-in-air sterilized polyethylene used in Hexloc liners. The newer Ringloc liner with the ArCom™ polyethylene has superior clinical results but a linear wear rate and frequency of osteolytic lesions that is higher than expected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients

BACKGROUND A number of excellent results with the cementless titanium femoral component of the Mallory Head Total Hip Replacement have been published. Unfortunately, these excellent results have been counteracted by the poor performance of the cementless titanium acetabular components. In 1994, the HexLoc acetabular component was replaced with a second-generation design, the RingLoc. We hypothe...

متن کامل

Early Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup

Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...

متن کامل

Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty

A finite element model has been developed to predict in vivo micro motion between a modular acetabular cup and liner after cement less total hip arthroplasty. The purpose of this study is to experimentally validate the model. Six LVDT sensors were used to monitor the micromotion of the liner when subjected to loading conditions ranging from 250 N to 5000 N. Deformations at points of interest fo...

متن کامل

Effect of elevated-rim acetabular liner and 32-mm femoral head on stability in total hip arthroplasty.

OBJECTIVE Although the theoretical attractions of the elevated rim are obvious and have been widely accepted as a mean to improve the postoperative stability, the clinical advantages have not been demonstrated. The aim of this study is to further evaluate the elevated liners contribution to stability. METHODS Forty-six patients with 50 hips undergoing primary total hip arthroplasty (THA) were...

متن کامل

Enhanced Stability of Total Hip Replacement Implants Resulting from Use of an Elevated-Rim Acetabular Liner and 32-mm Femoral Head

The use of an elevated-rim acetabular liner in total hip arthroplasty (THA) is widely accepted. We sought to determine quantitatively the amount of additional stability provided by the elevated-rim liner as compared to the standard non-elevated liner. Furthermore, the stability of the hip with a 32-mm femoral head was compared to the standard 28-mm head. Our results show that a 15° elevated-rim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009