Accuracy of [18Fluorine]-Fluoro-2-Deoxy-d-Glucose Positron Emission Tomography-Computed Tomography Response Assessment Following (Chemo)radiotherapy for Locally Advanced Laryngeal/Hypopharyngeal Carcinoma
نویسندگان
چکیده
INTRODUCTION The accuracy of response assessment positron emission tomography (PET)-computed tomography (CT) following radiotherapy with or without chemotherapy for laryngeal/hypopharyngeal squamous cell carcinoma is uncertain. METHODS In all, 35 patients with laryngeal or hypopharyngeal squamous cell carcinoma who were treated between 2009 and 2014 with (chemo)radiotherapy were identified. The accuracy of response assessment PET-CT was made by correlation with clinical follow-up and pathological findings. RESULTS Of the 35 patients, 20 (57%) had an overall complete metabolic response. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for response assessment [18Fluorine]-fluoro-2-deoxy-d-glucose (FDG) PET-CT for primary and nodal sites, respectively, were 100%, 73%, 46%, and 100% and 83%, 95%, 83%, and 95%. CONCLUSIONS Response assessment FDG PET-CT following (chemo)radiotherapy for laryngeal and hypopharyngeal carcinomas has a high NPV for both primary site and lymph nodes and can be used to guide treatment decisions. The PPV of residual FDG uptake at the primary tumour site is limited and requires examination and biopsy confirmation.
منابع مشابه
Staging of Laryngeal and Hypopharyngeal Cancer: Computed Tomography versus Histopathology
Introduction: Computed tomography (CT) imaging is the choice of investigation for evaluation of extent of tumor under the mucosa, locally and regionally. This study was undertaken to assess the accuracy of preoperative CT imaging in the staging of carcinoma of the larynx and hypopharynx. Materials and Methods: In this retrospective study, all cases who were clinically (c) staged T3–T4 and w...
متن کاملImaging in lung cancer: positron emission tomography scan.
In the past 5 yrs, positron emission tomography (PET), usually used with 18F-fluoro-2-deoxy-glucose (FDG), has become an important imaging modality in lung cancer patients. Currently, the use of FDG-PET in respiratory oncology is mainly for diagnosis and staging. Standard indications are the evaluation of an indeterminate solitary pulmonary nodule or mass, where FDG-PET has proven to be signifi...
متن کاملLong-term complete response in a breast cancer patient with skeletal muscle metastases diagnosed using 18F-FDG-PET
Common sites for metastatic spreading from breast cancer are bones, lungs and liver, the skeletal muscle being an unusual site. Although rare, when skeletal muscle metastases occur they are associated with a poor prognosis. These metastases are clinically difficult to diagnose since they can be found without pain symptoms. Radiologically, magnetic resonance imaging has been considered better th...
متن کاملResponse monitoring by positron emission tomography during radiotherapy of a squamous cell skin carcinoma.
BACKGROUND Radiotherapy of skin cancer in a previously irradiated area is a challenging task with regard to cumulative total dose and consecutive normal tissue toxicity. Methods of biological response monitoring might be helpful in achieving a favorable therapeutic ratio. PATIENT AND METHODS We report the case of a 77-year-old patient with squamous cell skin carcinoma originating within a pre...
متن کاملDiagnostic role and limitations of 2-deoxy-2-(F-18) fluoro- D-Glucose positron emission tomography (FDG-PET) in screening of synchronous cancer of other organs in patients with head and neck cancers
Patients with Head and Neck Squamous Cell Carcinoma (HNSCC) often develop synchronous primary cancers. It is important to detect synchronous cancer in HNSCC patients, because it influences treatment selection of primary cancer. The aim of the study was to evaluate the diagnostic role and limitations of pre-treatment 2-deoxy-2(F-18) Fluoro-D-Glucose Positron Emission Tomography (FDG-PET) in pati...