Neuro-Genetic Optimization of the Diffuser Elements for Applications in a Valveless Diaphragm Micropumps System

نویسندگان

  • Hing Wah Lee
  • Ishak H. Abdul Azid
چکیده

In this study, a hybridized neuro-genetic optimization methodology realized by embedding numerical simulations trained artificial neural networks (ANN) into a genetic algorithm (GA) is used to optimize the flow rectification efficiency of the diffuser element for a valveless diaphragm micropump application. A higher efficiency ratio of the diffuser element consequently yields a higher flow rate for the micropump. For that purpose, optimization of the diffuser element is essential to determine the maximum pumping rate that the micropump is able to generate. Numerical simulations are initially carried out using CoventorWare® to analyze the effects of varying parameters such as diffuser angle, Reynolds number and aspect ratio on the volumetric flow rate of the micropump. A limited range of simulation results will then be used to train the neural network via back-propagation algorithm and optimization process commence subsequently by embedding the trained ANN results as a fitness function into GA. The objective of the optimization is to maximize the efficiency ratio of the diffuser element for the range of parameters investigated. The optimized efficiency ratio obtained from the neuro-genetic optimization is 1.38, which is higher than any of the maximum efficiency ratio attained from the overall parametric studies, establishing the superiority of the optimization method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Reynolds Number Flow Through Nozzle-Diffuser Elements in Valveless Micropumps

Flow characteristics of low Reynolds number laminar flow through gradually expanding conical and planar diffusers were investigated. Such diffusers are used in valveless micropumps to effect flow rectification and thus lead to pumping action in one preferential direction. Four different types of diffuser flows are considered: fully developed and thin inlet boundary layer flows through conical a...

متن کامل

Design and Simulation of Valve Less PZT Micropump for Drug Delivery System

In this paper some discrete parts of an electrostatic and flat-walled self-aligned valveless, micropump for drug delivery system is designed and simulated. The core component of the system is a piezoelectric diaphragm that can convert the reciprocating movement of a diaphragm actuated by a piezoelectric actuator into a pumping effect. The deflection in the diaphragm was analyzed by applying the...

متن کامل

Design and Fabrication of MEMS Micropumps using Double Sided Etching

In this paper, we report a simple technique for the fabrication of planar valveless micropumps. The technique utilizes MEMS fabrication methods by using a double sided etch technique. Instead of using several masks and process steps, an anisotropic wet etch technique at both sides of a silicon substrate is implemented at the same time for creating the pump membrane and the diffuser/ nozzle elem...

متن کامل

Investigation of Simple Process Technology for the Fabrication of Valveless Micropumps

This paper presents a simple process technique for the fabrication of valveless micropumps. The process design utilizes standard MEMS process using double-sided anisotropic silicon wet etching process with an additional adhesive bonding technique. The diffuser and nozzle element of the pump with depth of 50 μm, as well as a 150 μm thick silicon membrane are designed and fabricated using only 3 ...

متن کامل

Laser-based fabrication of polymer micropump

Joohan Kim Xianfan Xu Purdue University School of Mechanical Engineering West Lafayette, Indiana 47907 E-mail: [email protected] Abstract. Diffuser micropumps are commonly fabricated using the standard lithography techniques with silicon as the base material. The important components of this type of micropumps are flow-directing diffusers and a moving diaphragm. Different diffuser designs show...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009