Diffusion-weighted imaging of the spine with a non-carr-purcell-meiboom-gill single-shot fast spin-echo sequence: initial experience.
نویسندگان
چکیده
BACKGROUND AND PURPOSE To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher (P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 x 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.
منابع مشابه
Multi-shot Diffusion-Weighted Split-Echo PROPELLER MRI of the Abdomen
Introduction Diffusion-weighted MRI (DWI) provides a non-invasive method for in vivo evaluation of tissue water mobility. Most DWI studies employ single-shot DWEPI techniques which can suffer severe artifacts and image distortion in abdominal imaging applications. Multi-shot TSE-based DW-PROPELLER [1] may overcome these limitations. DW-PROPELLER for brain [2] and abdominal [3] imaging has demon...
متن کاملDiffusion tensor imaging of the human optic nerve using a non-CPMG fast spin echo sequence.
PURPOSE To investigate the diffusion tensor properties of the human optic nerve in vivo using a non-Carr-Purcell-Meiboom-Gill (CPMG) fast spin echo (FSE) sequence. MATERIALS AND METHODS This non-CPMG FSE sequence, which is based on a quadratic phase modulation of the refocusing pulses, allows diffusion measures to be acquired with full signal and without artifacts from geometric distortions d...
متن کاملDiffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.
There is a need for an imaging sequence that can provide high-resolution diffusion tensor images at 3T near air-tissue interfaces. By employing a radial fast spin-echo (FSE) collection in conjunction with magnitude filtered back-projection reconstruction, high-resolution diffusion-weighted images can be produced without susceptibility artifacts. However, violation of the Carr-Purcell-Meiboom-Gi...
متن کاملCarr-purcell-meiboom-gill (cpmg) Imaging of Prostate Cancer; Trading Time for Information: High Quality T2 Images and Quantitative T2 Values for Cancer Discrimination
Introduction: T2-weighted imaging (T2WI) is widely used in the clinical staging of prostate cancer and is typically performed using fast spin echo (FSE) imaging. While FSE reduces acquisition time compared to standard spin echo (SSE) imaging, it also produces image blurring that results from T2-related effects upon the point spread function not present with SSE. In the present study, we employe...
متن کاملAccelerated acquisition and reconstruction of non-CPMG fast spin echo sequences
Introduction: Quadratic phase modulation of the refocusing pulses in a fast spin echo (FSE) sequence [1,2] has been shown to sustain signal magnitude and phase regardless of the signal phase at the beginning of the echo train. This technique, also known as non-CPMG (Carr-Purcell-Meiboom-Gill) FSE, generates two sets of signals in a single echotrain, which typically are saved and reconstructed s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 3 شماره
صفحات -
تاریخ انتشار 2007