Water-fat separation with parallel imaging based on BLADE.
نویسندگان
چکیده
Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fat images with flexible echo shifting. Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER, alternatively termed as BLADE), in conjunction with IDEAL, yields Turboprop IDEAL (TP-IDEAL) and allows for decomposition of water and fat signal with motion correction. However, the flexibility of its parameter setting is limited, and the related phase correction is complicated. To address these problems, a novel method, BLADE-Dixon, is proposed in this study. This method used the same polarity readout gradients (fly-back gradients) to acquire in-phase and opposed-phases images, which led to less complicated phase correction and more flexible parameter setting compared to TP-IDEAL. Parallel imaging and undersampling were integrated to reduce scan time. Phantom, orbit, neck and knee images were acquired with BLADE-Dixon. Water-fat separation results were compared to those measured with conventional turbo spin echo (TSE) Dixon and TSE with fat saturation, respectively, to demonstrate the performance of BLADE-Dixon.
منابع مشابه
Regularized iterative reconstruction for undersampled BLADE and its applications in three-point Dixon water-fat separation.
In MRI, the suppression of fat signal is very important for many applications. Multipoint Dixon based water-fat separation methods are commonly used due to its robustness to B(0) homogeneity compared with other fat suppression methods, such as spectral fat saturation. The traditional Cartesian k-space trajectory based multipoint Dixon technique is sensitive to motion, such as pulsatile blood fl...
متن کاملWater Fat Separation with Undersampled TSE BLADE Based on Three Point Dixon
Introduction In the three-point Dixon water fat separation method, one in-phase echo and two out-of-phase echoes are sampled in Cartesian k-space trajectory conventionally [1][2]. The Cartesian sampling is sensitive to motions, such as from pulsation and flow, which cause artifacts degrading the image quality. To address this problem, a non Cartesian sampling method, TSE BLADE three-point Dixon...
متن کاملFree-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.
PURPOSE Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS Multiecho data are acquired using a motion-robust radial stack-of-stars three-dimensional GRE s...
متن کاملSeparation of Water and Fat Magnetic Resonance Imaging Signals Using Deep Learning with Convolutional Neural Networks
Purpose: A new method for magnetic resonance (MR) imaging water-fat separation using a convolutional neural network (ConvNet) and deep learning (DL) is presented. Feasibility of the method with complex and magnitude images is demonstrated with a series of patient studies and accuracy of predicted quantitative values is analyzed. Methods: Water-fat separation of 1200 gradient-echo acquisitions f...
متن کاملCompressed sensing for chemical shift-based water-fat separation.
Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2013