The relationship of clinical QT prolongation to outcome in the conscious dog using a beat-to-beat QT-RR interval assessment.

نویسندگان

  • Anthony A Fossa
  • Michael J DePasquale
  • David L Raunig
  • Michael J Avery
  • Derek J Leishman
چکیده

QT interval prolongation of the electrocardiogram has been associated with the occurrence of life-threatening fatal ventricular arrhythmias. To understand the relationship between preclinical cardiac conduction assessment to clinical outcome, comparisons of free (unbound)-plasma drug concentrations and their associated effects in the conscious mongrel dog were made to the free plasma concentrations in humans reported to produce QT prolongation. E-4031 (an experimental class III antiarrhythmic), cisapride, terfenadine, terodiline, and verapamil all affect cardiac repolarization and can produce QT prolongation in humans. In the conscious dog, the QT interval was assessed on a beat-to-beat basis in relation to each preceding RR interval at concentrations approximating the same unbound human concentrations. E-4031, cisapride and terodiline statistically increased the QT(RR1000) interval [the QT interval at a 60 beats/min (bpm) heart rate] 23, 8, and 9 ms, respectively, at concentrations 0.3 to 15.8 times their relevant clinical level. Increases were not observed for terfenadine or verapamil (p > 0.05 at all doses). Inspection of individual dog QT versus RR interval relationships showed clear QT interval responses specific to each treatment but not readily apparent when data are averaged at a heart rate of 60 bpm. For specific rectifier K(+) current (IKr) blockers, robust effects on mean QT prolongation can be detected. However, for drugs that affect repolarization through multiple channels, the effect on the mean QT interval may be more difficult to detect. Inspection of the beat-to-beat QT-RR interval relationship in an individual animal can increase the sensitivity for more accurate clinical prediction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing QT prolongation and electrocardiography restitution using a beat-to-beat method.

Historically, the heart rate corrected QT (QTc) interval has been the standard method to assess for impaired ventricular repolarization, particularly for drug development. However, QTc does not reflect changes in autonomic state or QT-RR hysteresis which can also affect the interpretation of arrhythmogenic risk. With the advent of more accurate algorithms to automatically measure the QT interva...

متن کامل

Dynamic beat-to-beat modeling of the QT-RR interval relationship: analysis of QT prolongation during alterations of autonomic state versus human ether a-go-go-related gene inhibition.

Methods to correct the QT interval for heart rate are often in disagreement and may be further confounded by changes in autonomic state. This can be problematic when trying to distinguish the changes in QT interval by either drug-induced delayed repolarization or from autonomic-mediated physiological responses. Assessment of the canine dynamic QT-RR interval relationship was visualized by novel...

متن کامل

QT prolongation modifies dynamic restitution and hysteresis of the beat-to-beat QT-TQ interval relationship during normal sinus rhythm under varying states of repolarization.

The analysis of cardiac electrical restitution (the relationship between an action potential duration and its preceding diastolic interval) has been used to predict arrhythmia liability. However, the procedure to measure restitution is invasive and disrupts normal physiological autonomic balance. Dynamic analysis of sequential beat-to-beat ECG data was used to study restitution under normal sin...

متن کامل

Q-T interval prolongation in cirrhosis: Relationship and severity

Background: Cirrhosis as the final stage of progressive fibrosis of liver can affect other organs such as lungs, kidneys and heart. "Cirrhotic cardiomyopathy" involves the electrophysiological abnormalities such as QT interval prolongation. We assessed correlation between corrected QT interval prolongation and severity of cirrhosis based on Child Classification in each ECG lead. ...

متن کامل

Beat-to-beat QT variability and cardiac autonomic regulation.

MODERN ELECTROCARDIOGRAPHIC (ECG) equipment allows easy collection of large volumes of digital signals. Their computer processing facilitates a number of ECG measurements that were previously unobtainable. Among such measurements, beat-to-beat QT interval variability has attracted some popularity and has been investigated in a variety of physiological and clinical conditions (3, 9, 11, 15–17, 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of pharmacology and experimental therapeutics

دوره 302 2  شماره 

صفحات  -

تاریخ انتشار 2002