Sample size calculation for clinical trials using magnetic resonance imaging for the quantitative assessment of carotid atherosclerosis.
نویسندگان
چکیده
PURPOSE To provide sample size calculation for the quantitative assessment of carotid atherosclerotic plaque using non-invasive magnetic resonance imaging in multi-center clinical trials. METHODS. As part of a broader double-blind randomized trial of an experimental pharmaceutical agent, 20 asymptomatic placebo-control subjects were recruited from 5 clinical sites for a multi-center study. Subjects had 4 scans in 13 weeks on GE 1.5 T scanners, using TOF, T1-/PD-/T2- and contrast-enhanced Tl-weighted images. Measurement variability was assessed by comparing quantitative data from the index carotid artery over the four time points. The wall/outer wall (W/OW) ratio was calculated as wall volume divided by outer wall volume. The percent lipid-rich/necrotic core (%LR/NC) and calcification (%Ca) were measured as a proportion of the vessel wall. For %LR/NC and %Ca, only those subjects that exhibited LR/NC or Ca components were used in the analysis. RESULTS Measurement error was 5.8% for wall volume, 3.2% for W/OW ratio, 11.1% for %LR/NC volume and 18.6% for %Ca volume. Power analysis based on these values shows that a study with 14 participants in each group could detect a 5% change in W/OW ratio, 10% change in wall volume, and 20% change in %LR/NC volume (power = 80%, p < .05). The calculated measurement errors presume any true biological changes were negligible over the 3 months that subjects received placebo. CONCLUSION In vivo MRI is capable of quantifying plaque volume and plaque composition, such as %lipid-rich/necrotic core and %calcification, in the clinical setting of a multi-center trial with low inter-scan variability. This study provides the basis for sample size calculation of future MRI trials.
منابع مشابه
Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage
Carotid artery atherosclerosis is a major cause of ischemic stroke. For more than 30 years, future stroke risk and carotid stroke etiology have been determined using percent diameter stenosis based on clinical trials in the 1990s. In the past 10 years, magnetic resonance imaging (MRI) sequences have been developed to detect carotid intraplaque hemorrhage. By detecting carotid intraplaque hemorr...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملHigh field MR carotid vessel wall imaging: reproducibility of five different MR-weightings
Introduction Magnetic Resonance Imaging (MRI) has emerged as a promising noninvasive imaging modality for the serial assessment of vessel wall thickness in the carotid artery as an early marker of atherosclerosis. For clinical application of this technique, Scan-Rescan reproducibility is paramount. Currently, a multicontrast protocol, including a combination of MR-weightings is used as referenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2005