Sample size calculation for clinical trials using magnetic resonance imaging for the quantitative assessment of carotid atherosclerosis.

نویسندگان

  • Tobias Saam
  • William S Kerwin
  • Baocheng Chu
  • Jianming Cai
  • Annette Kampschulte
  • Thomas S Hatsukami
  • Xue-Qiao Zhao
  • Nayak L Polissar
  • Blazej Neradilek
  • Vasily L Yarnykh
  • Kelly Flemming
  • John Huston
  • William Insull
  • Joel D Morrisett
  • Scott D Rand
  • Kevin J DeMarco
  • Chun Yuan
چکیده

PURPOSE To provide sample size calculation for the quantitative assessment of carotid atherosclerotic plaque using non-invasive magnetic resonance imaging in multi-center clinical trials. METHODS. As part of a broader double-blind randomized trial of an experimental pharmaceutical agent, 20 asymptomatic placebo-control subjects were recruited from 5 clinical sites for a multi-center study. Subjects had 4 scans in 13 weeks on GE 1.5 T scanners, using TOF, T1-/PD-/T2- and contrast-enhanced Tl-weighted images. Measurement variability was assessed by comparing quantitative data from the index carotid artery over the four time points. The wall/outer wall (W/OW) ratio was calculated as wall volume divided by outer wall volume. The percent lipid-rich/necrotic core (%LR/NC) and calcification (%Ca) were measured as a proportion of the vessel wall. For %LR/NC and %Ca, only those subjects that exhibited LR/NC or Ca components were used in the analysis. RESULTS Measurement error was 5.8% for wall volume, 3.2% for W/OW ratio, 11.1% for %LR/NC volume and 18.6% for %Ca volume. Power analysis based on these values shows that a study with 14 participants in each group could detect a 5% change in W/OW ratio, 10% change in wall volume, and 20% change in %LR/NC volume (power = 80%, p < .05). The calculated measurement errors presume any true biological changes were negligible over the 3 months that subjects received placebo. CONCLUSION In vivo MRI is capable of quantifying plaque volume and plaque composition, such as %lipid-rich/necrotic core and %calcification, in the clinical setting of a multi-center trial with low inter-scan variability. This study provides the basis for sample size calculation of future MRI trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage

Carotid artery atherosclerosis is a major cause of ischemic stroke. For more than 30 years, future stroke risk and carotid stroke etiology have been determined using percent diameter stenosis based on clinical trials in the 1990s. In the past 10 years, magnetic resonance imaging (MRI) sequences have been developed to detect carotid intraplaque hemorrhage. By detecting carotid intraplaque hemorr...

متن کامل

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Size Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions

We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...

متن کامل

Size Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions

We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...

متن کامل

High field MR carotid vessel wall imaging: reproducibility of five different MR-weightings

Introduction Magnetic Resonance Imaging (MRI) has emerged as a promising noninvasive imaging modality for the serial assessment of vessel wall thickness in the carotid artery as an early marker of atherosclerosis. For clinical application of this technique, Scan-Rescan reproducibility is paramount. Currently, a multicontrast protocol, including a combination of MR-weightings is used as referenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2005