Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors.
نویسندگان
چکیده
UNLABELLED A high-sensitivity, high-resolution brain PET scanner ("G-PET") has been developed. This scanner is similar in geometry to a previous brain scanner developed at the University of Pennsylvania, the HEAD Penn-PET, but the detector technology and electronics have been improved to achieve enhanced performance. METHODS This scanner has a detector ring diameter of 42.0 cm with a patient aperture of 30.0 cm and an axial field of view of 25.6 cm. It comprises a continuous light-guide that couples 18,560 (320 x 58 array) 4 x 4 x 10 mm(3) gadolinium oxyorthosilicate (GSO) crystals to 288 (36 x 8 array) 39-mm photomultiplier tubes in a hexagonal arrangement. The scanner operates only in 3-dimensional (3D) mode because there are no interplane septa. Performance measurements on the G-PET scanner were made following National Electrical Manufacturers Association NU 2-2001 procedures for most measurements, although NU 2-1994 procedures were used when these were considered more appropriate for a brain scanner (e.g., scatter fraction and counting-rate performance measurements). RESULTS The transverse and axial resolutions near the center are 4.0 and 5.0 mm, respectively. At a radial offset of 10 cm, these numbers deteriorate by approximately 0.5 mm. The absolute sensitivity of this scanner measured with a 70-cm long line source is 4.79 counts per second (cps)/kBq. The scatter fraction measured with a line source in a 20-cm-diameter x 19-cm-long cylinder is 39% (for a lower energy threshold of 410 keV). For the same cylinder, the peak noise equivalent counting rate is 60 kcps at an activity concentration of 7.4 kBq/mL (0.20 micro Ci/mL), whereas the peak true coincidence rate is 132 kcps at an activity concentration of 14 kBq/mL (0.38 micro Ci/mL). Images from the Hoffman brain phantom as well as (18)F-FDG patient scans illustrate the high quality of images acquired on the G-PET scanner. CONCLUSION The G-PET scanner attains the goal of high performance for brain imaging through the use of an Anger-logic GSO detector design with continuous optical coupling. This detector design leads to good energy resolution, which is needed in 3D imaging to minimize scatter and random coincidences.
منابع مشابه
Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET.
UNLABELLED Quantitative PET with (15)O provides absolute values for cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)), and oxygen extraction fraction (OEF), which are used for assessment of brain pathophysiology. Absolute quantification relies on physically accurate measurement, which, thus far, has been achieved by 2-dimensional PET (2D PET), t...
متن کاملDesign study of dedicated brain PET with polyhedron geometry.
BACKGROUND Despite being the conventional choice, whole body PET cameras with a 76 cm diameter ring are not the optimal means of human brain imaging. OBJECTIVE In fact, a dedicated brain PET with a better geometrical structure has the potential to achieve a higher sensitivity, a higher signal-to-noise ratio, and a better imaging performance. METHODS In this study, a polyhedron geometrical d...
متن کاملPET Radiopharmaceuticals
PET (positron emission tomography) is a powerful imaging technique that can provide quantitative information on the distribution of positron emitter labeled radiopharmaceuticals (PET radiopharmaceuticals) in the body. Positrons (ß+) are positively charged beta particles. They are emitted when the atom is proton rich. A positron has only a transient existence. After losing all of its kinetic ene...
متن کاملPET Radiopharmaceuticals
PET (positron emission tomography) is a powerful imaging technique that can provide quantitative information on the distribution of positron emitter labeled radiopharmaceuticals (PET radiopharmaceuticals) in the body. Positrons (ß+) are positively charged beta particles. They are emitted when the atom is proton rich. A positron has only a transient existence. After losing all of its kinetic ene...
متن کاملPerformance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
UNLABELLED PET combined with CT has proven to be a valuable multimodality imaging device revealing both functional and anatomic information. Although PET/CT has become completely integrated into routine clinical application and also has been used in small-animal imaging, CT provides only limited soft-tissue contrast and, in preclinical studies, exposes the animal to a relatively high radiation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 44 8 شماره
صفحات -
تاریخ انتشار 2003