Alternatives for coupling sequential injection systems to commercial capillary electrophoresis-mass spectrometry equipment.

نویسندگان

  • B Santos
  • B M Simonet
  • B Lendl
  • A Ríos
  • M Valcárcel
چکیده

On-line coupling of an automated flow system with a commercially available capillary electrophoresis (CE) system with an electrospray interface (ESI) for mass spectroscopic (MS) detection is described. The peculiarities of CE-ESI-MS interfaces, in which a high electrical field must be applied to the capillary end where the sample is provided by the flow system, introduce significant difficulties for the appropriate work of the entire arrangement. Experimental strategies are proposed for achieving stable conditions for on-line sample pre-treatment, conditioning of the separation capillary, sample injection, as the proper separation. The versatility and robustness of the proposed arrangement is discussed, taken as example the separation of a variety of amines. Connection of the CE system's pressure to the automated flow system enables hydrodynamic introduction of sample with high precision. The developed hyphenated system is of practical relevance as it opens an avenue for the simplification and automation of the whole analytical process required when using powerful CE-ESI-MS equipments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A soft on-column metal coating procedure for robust sheathless electrospray emitters used in capillary electrophoresis-mass spectrometry.

An on-column metal coating procedure was developed for sheathless electrospray emitters, based on Justus von Liebig's electroless silver mirror reaction followed by electrochemical deposition of gold onto the silver layer. The coating procedure is straightforward, mild, inexpensive, and can be performed with standard laboratory equipment. A long-term (600 h) stability investigation of the condu...

متن کامل

Integrated system for high-throughput protein identification using a microfabricated device coupled to capillary electrophoresis/nanoelectrospray mass spectrometry.

An integrated microsystem providing rapid analyses of trace-level tryptic digests for proteomics application is presented. This modular microsystem includes an autosampler and a microfabricated device comprising a sample introduction port and an array of separation channels together with a low dead-volume facilitating the interface to nanoelectrospray mass spectrometry. Sequential injection and...

متن کامل

Hadamard transform time-of-flight mass spectrometry: a high-speed detector for capillary-format separations.

This work demonstrates that with an intrinsic duty cycle of 50% and spectral storage speeds up to 277 spectra s(-1) Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is a promising detector for any capillary-format separation that can be coupled to MS by electrospray ionization. Complete resolution of the components of a nine-peptide standard was achieved by coupling pressurized-ca...

متن کامل

Bottom-Up Proteomics of Escherichia coli Using Dynamic pH Junction Preconcentration and Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry

We report the use of the dynamic pH junction based capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for bottom-up proteomics with an electrokinetically pumped sheath-flow nanospray capillary electrophoresis-mass spectrometry (CE-MS) interface and both LTQ-XL and LTQ-Orbitrap-Velos mass spectrometers. Conventional injection of 20 nL of a 1 mg/mL BSA...

متن کامل

Peptide and protein characterization by high-rate electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry.

The analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-inject...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1127 1-2  شماره 

صفحات  -

تاریخ انتشار 2006