Accuracy of pleth variability index compared with inferior vena cava diameter to predict fluid responsiveness in mechanically ventilated patients
نویسندگان
چکیده
In the intensive care unit (ICU), stable hemodynamics are very important. Hemodynamic intervention is often effective against multiple organ failure, such as in tissue hypoxia and shock. The administration of intravenous fluids is the first step in regulating tissue perfusion.The main objective of this study is to compare the performance between 2 methods namely pleth variability index (PVI) and IVC distensibily index (dIVC).In this study, the hemodynamic measurements were performed before and after passive leg raising (PLR). Measurements were obtained, including, PVI, dIVC, and cardiac index (CI). Both CI and dIVC measurements were evaluated by transesophageal probe and convex probe respectively. The dIVC measurements were taken using M-mode, 2 cm from junction between the right atrium and the inferior vena cava. The PVI was measured by Masimo Radical-7 monitor, Masimo.A total of 72 patients were included. The dIVC at a threshold value of >23.8% provided 80% sensitivity and 87.5% specificity to predict fluid responsiveness and was statistically significant (P < .001), with an AUC 0.928 (0.842-0.975). The PVI at a threshold value of >14% provided 95% sensitivity and 81.2% specificity to predict fluid responsiveness and was statistically significant (P < .001), with an AUC 0.939 (0.857-0.982).Both PVI and dIVC can be used as a noninvasive method that can be easily applied at the bedside in determining fluid responsiveness in all patients with mechanical ventilation in intensive care.
منابع مشابه
Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation
BACKGROUND To evaluate the efficacy of using internal jugular vein variability (IJVV) as an index of fluid responsiveness in mechanically ventilated patients after cardiac surgery. METHODS Seventy patients were assessed after cardiac surgery. Hemodynamic data coupled with ultrasound evaluation of IJVV and inferior vena cava variability (IVCV) were collected and calculated at baseline, after a...
متن کاملRespiratory variation in inferior vena cava diameter: surrogate of central venous pressure or parameter of fluid responsiveness? Let the physiology reply
In the previous issue of Critical Care, Muller and colleagues investigated whether respiratory variation in inferior vena cava diameter (ΔIVC) could be a useful predictor of fluid responsiveness in spontaneously breathing patients. The study concludes that accuracy was not very good and therefore that this parameter should be used with caution in these patients. There is still confusion about t...
متن کاملJugular vein distensibility predicts fluid responsiveness in septic patients
INTRODUCTION The purpose of the study was to verify the efficacy of using internal jugular vein (IJV) size and distensibility as a reliable index of fluid responsiveness in mechanically ventilated patients with sepsis. METHODS Hemodynamic data of mechanically ventilated patients with sepsis were collected through a radial arterial indwelling catheter connected to continuous hemodynamic monito...
متن کاملCan Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review
Introduction. We systematically evaluated the use of transthoracic echocardiography in the assessment of dynamic markers of preload to predict fluid responsiveness in the critically ill adult patient. Methods. Studies in the critically ill using transthoracic echocardiography (TTE) to predict a response in stroke volume or cardiac output to a fluid load were selected. Selection was limited to E...
متن کاملRight internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness
OBJECTIVE To investigate whether the respiratory variation of the inferior vena cava diameter (∆DIVC) and right internal jugular vein diameter (∆DRIJ) are correlated in mechanically ventilated patients. METHODS This study was a prospective clinical analysis in an intensive care unit at a university hospital. Thirty-nine mechanically ventilated patients with hemodynamic instability were includ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2017