Quantitative assessment of scanning-system parameters.
نویسندگان
چکیده
a recognized need to investigate radio nuclide scanning on a system basis beginning with the radiopharmaceutical and the clinical problem and encompassing the instrumentation and observer performance. To be effective such investigations must be based upon quantitative measurement of sys tem performance over a range of system-design pa rameters and over a range of medical problems. Although many investigators have measured the performance of discrete components, there has been no systematic investigation of the entire scanning system. This has been due largely to the difficulties associated with varying realistic phantom organs and real detector systems and the time consumed in repeating tests to compensate for statistical flue tuations. Similarly, the limited availability of appro priate data-storage and data-processing equipment has prevented effective exploration of the effects of data processing on performance. Techniques and instrumentation have now been developed to overcome these limitations based on a combination of scanning hardware components and digital simulation to form a system for quantitatively investigating all parameters of the scanning tech nique. The system provides the capability for study ing the effects on image interpretation due to physical characteristics of the radionuclide, charac tenistics of the clinical problem, characteristics of the detector and effects of various data-processing operations. In this system the input data are pro vided by either a digital simulation of a scanning system viewing an organ or alternatively by a scan ner at the Johns Hopkins Medical Institutions scan fling a phantom or a patient. The digital simulation of a particular organ and detector provides the detector-output data in a form representing a normalized scan without statistical fluctuation noise. Stored data from these scans are then operated on by a general-purpose computer which is programmed to introduce the parameters associated with activity levels, lesion size and loca tion, detector efficiency and scanning time, among others. After being transformed to include quantum fluctuation noise, these data represent a complete simulation of a scan. These simulation data are processed in an on-line digital computer and pre sented on a digitally-controlled, TV-like display. The effect of the combined parameters of the system are studied by measuring the performance of ob servers in detecting and characterizing lesions. The value of computed quantities such as area counts in assisting the visual evaluation of a scan can be assessed. Many different parameters can be rapidly varied, and large numbers of tests can be run so that quantitative results …
منابع مشابه
The porosity assessment of thermal barrier coatings obtained by APS method
Purpose: The article presents the outline of methods and range of microstructural assessment of ceramic coatings, using the example of thermal barrier coatings. The major structural parameters describing the quality of the barrier layers have been characterised as well as the problems related to the correct metallographic specimen preparation and the methodology of their assessment. Design/meth...
متن کاملQuantitative assessment of salivary gland function by radioisotopic scanning in a randomized trial of Pilocarpine for prevention of radiation induced Xerostomia [Persian]
Introduction: Radioisotope scanning is the best method for objective assessment of salivary gland function. Thus, it was used in a randomized trial of concomitant pilocarpine for assessment of radiation-induced xerostomia, in addition to subjective evaluation by an approved questionnaire and objective standard xerostomia grading. Methods: Patients randomized in placebo-controlled trial of...
متن کاملRole of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot
OBJECTIVE To assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity. RESEARCH DESIGN AND METHODS Forty-two patients with acute (n = 21) and nonacute (n = 21) CNO underwent quantitative bone scanning. Patients with acute CNO were followed for 3-12 months and bone scans were repeated after treatment. New quantitative parameters were assessed ...
متن کاملEvaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging
Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...
متن کاملQuantitative Safety and Health Assessment Based on Fuzzy Inference and AHP at Preliminary Design Stage
Quantitative assessment is the most important means to identify hazard potential and manage risk for an industrial process. The implement of quantitative assessment in the early stage will help to develop inherently safer process, eliminating the hazard and reduce the possibility of accidental chain events and the magnitude of consequences. In this paper, after reviewing the presently available...
متن کاملQuantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics
Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 11 2 شماره
صفحات -
تاریخ انتشار 1970