Post-operative alopecia after robotic surgery in steep Trendelenburg position: a restated observation of pressure alopecia.
نویسندگان
چکیده
Postoperative alopecia is an uncommon complication and its outcome is aesthetically drastic. Although its mechanism has not been clearly elucidated, a proposed risk factor is steep Trendelenburg positioning (30-40 degrees) that is frequently used during robotic gynecologic surgeries. We report a case of postoperative alopecia in 53-year-old female patient who had undergone robotic-assisted laparoscopic hysterectomy and bilateral salpingoophorectomy with sacrocolpopexy and cystoscopy. Prevention of alopecia with proper head positioning, avoidance of mechanical compression by rigid objects and maintenance of intraoperative hemodynamics is of utmost importance for anesthesiologists.
منابع مشابه
Ocular parameters before and after steep Trendelenburg positioning for robotic-assisted laparoscopic radical prostatectomy
PURPOSE Intraocular pressure (IOP) increases in patients in a steep Trendelenburg position during robotic-assisted laparoscopic radical prostatectomy (RALP). We hypothesized that a steep Trendelenburg position during RALP, an unusual systemic condition involving a transiently increased IOP, may induce ocular pathology that can be detected by detailed evaluations long after the surgery. This stu...
متن کاملCerebral haemodynamic physiology during steep Trendelenburg position and CO(2) pneumoperitoneum.
BACKGROUND The steep (40°) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to elucidate the influence of this patient positioning on cerebral blood flow and zero flow pressure (ZFP), and to assess the validity of different methods of evaluating ZFP. METHODS In 21 consecutive patients who underwent robotic endoscopic radical pr...
متن کاملDoes Restrictive Fluid Strategy during Robotic Pelvic Surgeries Obtund Intraoperative Rise in Intraocular Pressure?
Background Robotic pelvic surgeries require steep Trendelenburg position which may result in rise in intraocular pressure (IOP). Aim The aim of this study was to compare the changes that occur in IOP during robotic pelvic surgeries in steep Trendelenburg position with a restrictive intravenous fluid administration. Settings and Design This prospective observational study was conducted in a ...
متن کاملInfluence of steep Trendelenburg position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy.
BACKGROUND The steep (40 degrees ) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to investigate the combined effect of this position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during these procedures. METHODS Physiological data were recorded during the whole surgical procedure ...
متن کاملComparison of volume controlled ventilation and pressure controlled ventilation in patients undergoing robot-assisted pelvic surgeries: An open-label trial
BACKGROUND AND AIMS Although volume controlled ventilation (VCV) has been the traditional mode of ventilation in robotic surgery, recently pressure controlled ventilation (PCV) has been used more frequently. However, evidence on whether PCV is superior to VCV is still lacking. We intended to compare the effects of VCV and PCV on respiratory mechanics and haemodynamic in patients undergoing robo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Middle East journal of anaesthesiology
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2013