The determination of metals in blood serum by atomic absorption spectroscopy-I

نویسندگان

  • B. KRAMER
  • E. P. CLARK
  • T. A. HARPER
  • J. W. FERREBEE
  • L. A. SAPIRSTEIN
  • A. D. WINER
  • CREN
چکیده

Abstm&-The celcium content of blood mrum cm be accurately determined on 0.1-0.25 ml samples by atomic absorption measurements in an air-acetylene flame after removal of the proteins by coagulation and centrifuging. A fairly accurate value can be obtained more quickly from direct measurements on serum diluted with water, which may with advantage contain about 1 per cent of the disodium salt of ethylenediaminetetracetic acid. Serum calcium values obtained by atomic absorption spectroscopy are signifkantly higher than those obtained by the standard oxalate-permanganate procedure and support the conclusions of MACINTYRE [3] on the shortcomings of the chemical method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy

At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...

متن کامل

Indirect Determination of Ascorbic Acid by Atomic Absorption Spectroscopy

A new and simple method followed by atomic absorption spectrometry has been developedfor indirect determination of ascorbic acid (AA). The proposed method was based on the oxidationof AA to dehydroascorbic acid with Cu2+cation(200mgL-1)in an ammonium thiocyanatesolution atpH2.4. AA reduces Cu2+to Cu+followed by the precipitation of Cu+ with SCN-. Then, the excess ofCu2+in the solution was measu...

متن کامل

DEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE

Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...

متن کامل

Extraction and Determination of Heavy Metals Using Silver Coated Magnetic Nanoparticles and Flame Atomic Absorption Spectrometry

A rapid, simple and sensitive magnetic solid phase extraction (MSPE) method was developed for the pre-concentration and determination of copper and cadmium ions. In this study, modified Fe3O4@Ag nanoparticles were synthesized and then ligand 2-isonicotinoyl hydrazine carbodithiolate (ITHCDT) was bonded to silver due to the formation of covalent bond of S-Ag. In this method, copper and cadmium i...

متن کامل

Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy

Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001