High sensitivity detection of bisphenol A using liposome chromatography.

نویسندگان

  • Xue-Ying Liu
  • Chikashi Nakamura
  • Itsuro Tanimoto
  • Shiro Miyake
  • Noriyuki Nakamura
  • Takashi Hirano
  • Jun Miyake
چکیده

An antibody column in tandem with a fluorescent dye entrapped liposome column was developed for highly sensitive detection of an endocrine disruptor, bisphenol A (BPA). Anti-BPA antibody was immobilized in a protein G column with orientation control. A derivative of BPA was conjugated to phospholipase A2 (PLA2). BPA sample solutions mixed with the BPA-PLA2 conjugates were injected on to the anti-BPA antibody column and competitive binding occurred in the antibody column. The amount of the free conjugate was proportional to the concentration of the BPA sample. The eluted conjugates were injected on to the second column gel on which calcein-entrapped liposomes were immobilized and the PLA2-catalyzed hydrolysis of liposomal phospholipids causing fluorescent dye leakage as a signal amplification. In this system, the mixture of BPA and BPA-PLA2 conjugate were incubated for 60 min in the anti-BPA column, and then the collected solution was applied to the liposome column. The BPA detection range of 0.02-140 ng mL(-1) was wider than 0.03-6.6 ng mL(-1) obtained by the method of competitive ELISA using the same antibody. Moreover, this system could be adapted to an HPLC system resulting in almost the same detection limit in online detection. The method could be applied to environmental samples, river water and soil extracts. The BPA concentration of 0.1 ng mL(-1) and 10 ng g(-1) was detectable in water and soil extract, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of bisphenol A in beer by immunoaffinity column tandem high-performance liquid chromatography

KEYWORD: bisphenol A; immune-affinity column; high-performance liquid chromatography ABSTRACT: A rapid and sensitive method using immuno-affinity columns (IACs) as sample purification procedure and high-performance liquid chromatography (HPLC) tandem fluorescence detector (FLD) for detection has been developed for the determination of bisphenol A (BPA) in beer. The limit of detection (LOD) is 0...

متن کامل

The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography

Background: Several methods have been developed for detection of sequence variation in genes and each has its advantages and disadvantages. A disadvantage of them is that the simpler, cost-effective methods are commonly perceived as being less sensitive in their detection of sequence variation, whereas those with proven sensitivity have a requirement for complex or expensive laboratory equipmen...

متن کامل

Simultaneous determination of phenolic xenoestrogens by solid-phase extraction and high-performance liquid chromatography with fluorescence detection.

A highly sensitive and selective method for simultaneous determination of some hydroxyl group-containing endocrine disruptors, including bisphenol A (BPA), bisphenol B (BPB), bisphenol E (BPE), bisphenol F (BPF) and 4-nonylphenol (4-NP), was developed. The method consists of precolumn derivatization of the analytes, solid-phase extraction (SPE) and subsequent chromatographic analysis by high-pe...

متن کامل

Highly Electrocatalytic Oxidation of Bisphenol A at Glassy Carbon Electrode Modified with Metal-organic Framework MOF-508a and its Application in Real Sample Analysis

The use MOF-508a as sensing component for the precise discerning of bisphenol A via the electrochemical technique and its synthesis by a simple method were reported in the present study. Scanning electron microscopy (SEM) and x-ray diffraction (XRD) were applied to describe the MOF-508a’s composition and structure. In addition, MOF-508a was exploited so that the glassy carbon electrode could be...

متن کامل

Photocatalytic Degradation of Bisphenol A from Aqueous Solutions using TiO2 Nanoparticles and UV Illumination

Background and Purpose: Bisphenol A (BPA) is used to make certain plastics and epoxy resins. It is a non-biodegradable compound, and poses health risks to both humans and animals. The purpose of this study was to evaluate decomposition efficiency of BPA from aqueous solutions using UV irradiation. Materials and Methods: In this study, the photodegradation of BPA in water were carrie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytica chimica acta

دوره 578 1  شماره 

صفحات  -

تاریخ انتشار 2006