Accuracy and reproducibility of calibrations on the skin using the fives fluorescence monitor.

نویسنده

  • M W Roff
چکیده

Dermal contamination from products such as pesticide formulations may be measured by adding a fluorescent dye as a tracer, and photographing the glow of the dye on the skin under ultraviolet light. The Fluorescence Interactive Video Exposure System (FIVES) fluorescence monitor, developed at the Health and Safety Laboratory, uses calibrations of intensity of glow against surface concentration of dye which are affected by the natural fluorescence of the skin and by skin hue. Calibrations of two dye/product mixtures upon the skin of several volunteers showed that a simple multiplicative correction procedure aligned all the responses to one calibration curve for each mixture. The palms of the hands were an exception, because their natural fluorescence was much higher than other areas of skin, and the relation no longer held. A further correction factor aligned their responses with the rest. The calibration data were fitted best by log-log polynomials, although linear polynomials were acceptable. Using this new procedure, the FIVES monitor could estimate dermal contamination to within +/- 70% of known applied doses. Upon exposure to light, the dyes on the skin were found to fade by 20% in 1/2 h, but no further in 1 h. The procedure and calibrations developed here were used in an experiment to estimate the likely dermal exposures of amateur or occasional biocide users, painting ready-to-use wood preservative fluids onto a trellis fence outdoors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Diagnodent Accuracy in Detecting Approximal Caries in Primary Molars

Introduction: Detection of caries lesions on approximal surfaces of posterior teeth is difficult, since wide contact points hamper direct visual inspection. Due to the importance of the early detection of dental caries, the aim of this study is to compare the performance of different methods (visual, bitewing radiography and DIAGNOdent) in detecting approximal caries in primary molars. Methods:...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Preliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)

Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 1997