Accidental breakage of needle during subclavian vein catheterization: an adversity uncalled for!
نویسندگان
چکیده
Central venous catheter (CVC) placement is an essential component of modern-day critical care. Its use was first documented by Werner Forssman in 1929, and Seldinger perfected the technique in 1953.(1) Although CVC insertion is a routine practice, it is not devoid of complications. We report a rare event in which the introducer needle shaft was fractured from its hub during CVC insertion in the right subclavian vein. A 60-year-old male patient was admitted to the intensive care unit with septic shock. In the course of management, central venous catheterization of right subclavian vein was planned. After informed and written consent was obtained, necessary preparations were made. Initial ultrasound screening demonstrated a collapsible subclavian vein situated 4cm deep in the skin. The triple lumen CVC set (Romsons Scientific & Surgical Industries Pvt. Ltd., Agra, India. M/s, Romodex U. K. Ltd.) was assessed and flushed with heparinized saline. A Y-type introducer needle (18G; 70mm) was inserted under ultrasound guidance using an in-plane approach. Successful venous puncture required insertion of almost the full length of the needle, and the J-tipped guide wire was then inserted through the other port of the ‘Y’. When a sufficient length of the guide wire was inserted, needle removal was attempted. At this time, the needle shaft was fractured and separated from hub syringe assembly (Figure 1A). The hub syringe assembly was removed, and the visible tip of the fractured needle was grasped using hemostatic forceps. Maintaining constant outward pressure on the forceps and inward pressure on the guide wire, the fractured needle was removed carefully. The position of the guide wire was again confirmed with ultrasound, and the path was dilated with a dilator. CVC was railroaded over the guide wire, and the guide wire was removed. Close inspection revealed that the needle shaft was intact, and its breakage from the hub was the cause of the event (Figure 1B). Complications associated with CVC insertion fluctuate according to their definition and correlation with the multiple factors. Greater than 15% of patients experience catheter-related complications.(2) Mechanical complications occur in 5 19% of patients, infectious complications in 5 26% and thromboembolic complications in 2 26%.(3) Designing institutional standardized methods of CVC insertion is a logical process to promote prevention and decrease the incidence of complications. At our center, we routinely perform visual inspection of individual components of the CVC set and flush the catheter with saline prior to insertion. Additionally, all CVCs are inserted under ultrasound guidance, which allows any undue angulation of the needle to be avoided Conflicts of interest: None.
منابع مشابه
Influence of shoulder position on central venous catheter tip location during infraclavicular subclavian approach.
BACKGROUND Infraclavicular approach of the subclavian veins is commonly used for central venous access. However, aberrant catheter tip locations are frequently quoted for this approach. It was hypothesized that with the shoulder pulled downwards, the angle between the internal jugular and subclavian veins may increase, directing subclavian catheters into the internal jugular vein. This prospect...
متن کاملA catheter malpositioned patient with pain and paresthesia
We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...
متن کاملUltrasound-Guided Cannulation: Time to Bring Subclavian Central Lines Back.
Despite multiple advantages, subclavian vein (SCV) cannulation via the traditional landmark approach has become less used in comparison to ultrasound (US) guided internal jugular catheterization due to a higher rate of mechanical complications. A growing body of evidence indicates that SCV catheterization with real-time US guidance can be accomplished safely and efficiently. While several cannu...
متن کاملAnatomical variations of the clavicle and main vascular structures in two pediatric patients : subclavicular vein cannulation with supraclavicular approach
Introduction Central venous catheterization (CVC) is implemented for volume resuscitation, hemodynamic monitoring, vasopressor administration, frequent blood sampling, parenteral nutritional support and the administration of long-term chemotherapy [1]. Generally, it is attempted using the internal jugular, subclavian or femoral veins. The subclavian vein access has been the recommended approach...
متن کاملA systematic approach to ultrasound-guided central venous catheter placement—desirable modifications
With much interest we read the paper written by Saugel et al. [1] on a systemic approach to ultrasound-guided central vein catheterization. The article is comprehensive but some issues need discussing. The authors claim that the tip of the needle can be constantly identified while the needle is approaching the vein both in short-axis and long-axis views. This is inaccurate. The only approach wh...