Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis.
نویسندگان
چکیده
STUDY DESIGN An in vitro biomechanical study of adjacent segment motion (at L3-L4 and L5-S1) after a simulated lumbar interbody fusion of L4-L5 in different sagittal alignments was carried out. OBJECTIVES To test the hypothesis that an L4-L5 fixation in different sagittal alignments causes increased angular motion at the adjacent levels (L3-L4 and L5-S1) in comparison with the intact spine. SUMMARY OF BACKGROUND DATA Clinical experience has suggested that lumbar fusion in a nonanatomic sagittal alignment can increase degeneration of the adjacent levels. It has been hypothesized that this is the result of increased motion at these levels; however, to the authors' knowledge no mechanical studies have demonstrated this. METHODS Eight fresh human cadaveric lumbar spines (L3-S1) were biomechanically tested. Total angular motion at L3-L4 and L5-S1 under flexion-extension load conditions (7-Nm flexion and 7-Nm extension) was measured. Each specimen was tested intact, and then again after each of three different sagittal fixation angles (at L4-L5): (1) in situ (21 degrees lordosis), (2) hyperlordotic (31 degrees lordosis), and (3) hypolordotic (7 degrees lordosis). The simulated anterior/posterior fusion was performed at L4-L5 with pedicle screws posteriorly, vertebral body screws anteriorly, and an interbody dowel. RESULTS The averaged values for flexion-extension motion at L3-L4 were as follows: intact specimen 2.0 degrees, in situ fixation 4.0 degrees, hyperlordotic fixation 1.7 degrees, hypolordotic fixation 6.5 degrees. The averaged values for flexion-extension motions at L5-S1 were as follows: intact specimen 2.3 degrees, in situ fixation 2.6 degrees, hyperlordotic fixation 3.6 degrees, hypolordotic fixation 2.9 degrees. CONCLUSION Hypolordotic alignment at L4-L5 caused the greatest amount of flexion-extension motion at L3-L4, and the differences were statistically significant in comparison with intact specimen, in situ fixation, and hyperlordotic fixation. Hyperlordotic alignment at L4-L5 caused the greatest amount of flexion-extension motion at L5-S1, and the difference was statistically significant in comparison with intact specimen but not in situ fixation or hypolordotic fixation.
منابع مشابه
Biomechanical study on the effect of five different lumbar reconstruction techniques on adjacent-level intradiscal pressure and lamina strain.
OBJECT The objectives of this study were to compare the biomechanical effects of five lumbar reconstruction models on the adjacent segment and to analyze the effects of three factors: construct stiffness, sagittal alignment, and the number of fused segments. METHODS Nondestructive flexion-extension tests were performed by applying pure moments to 10 calf spinal (L3-S1) specimens. One-segment ...
متن کاملHigher Adjacent Segment Shear Forces after Simulated Lumbar Fusions with Reduced Lordosis
Introduction: Sagittal spinopelvic alignment has been shown to affect loads at the intervertebral joints and has been linked to spine health. Furthermore, the link between degenerative changes and loading of the IVD seems evident with pathophysiological loading widely thought to detrimentally affect the intervertebral disc. If changes in lumbosacral anatomy and kinematics are induced by lumbar ...
متن کاملBiomechanical Analysis of Fusion Segment Rigidity Upon Stress at Both the Fusion and Adjacent Segments: A Comparison between Unilateral and Bilateral Pedicle Screw Fixation
PURPOSE The purpose of this study was to investigate the effects of unilateral pedicle screw fixation on the fusion segment and the superior adjacent segment after one segment lumbar fusion using validated finite element models. MATERIALS AND METHODS Four L3-4 fusion models were simulated according to the extent of decompression and the method of pedicle screws fixation in L3-4 lumbar fusion....
متن کاملBiomechanics of coupled motion in the cervical spine during simulated whiplash in patients with pre-existing cervical or lumbar spinal fusion
OBJECTIVES Loss of motion following spine segment fusion results in increased strain in the adjacent motion segments. However, to date, studies on the biomechanics of the cervical spine have not assessed the role of coupled motions in the lumbar spine. Accordingly, we investigated the biomechanics of the cervical spine following cervical fusion and lumbar fusion during simulated whiplash using ...
متن کاملIs Cervical Sagittal Imbalance a Risk Factor for Adjacent Segment Pathomechanics After Multilevel Fusion?
STUDY DESIGN A biomechanical study using human spine specimens. OBJECTIVE The aim of this study was to assess whether the presence of cervical sagittal imbalance is an independent risk factor for increasing the mechanical burden on discs adjacent to cervical multilevel fusions. SUMMARY OF BACKGROUND DATA The horizontal offset distance between the C2 plumbline and C7 vertebral body (C2-C7 Sa...