Simulations of magnetic materials with MDGRAPE-2
نویسندگان
چکیده
of magnetic materials with MDGRAPE-2 B. G. Elmegreen R. H. Koch M. E. Schabes T. Crawford T. Ebisuzaki H. Furusawa T. Narumi R. Susukita K. Yasuoka The use of accelerator hardware for micromagnetics simulations is described, along with some initial results. The accelerator calculates the dipole interactions at 400 gigaflops, allowing large simulations to be performed with arbitrary geometries. Two research programs are highlighted, the simulation of a curved MRAM cell and the simulation of the write head in a computer disk drive.
منابع مشابه
Acceleration of Bluff Body Calculation Using Mdgrape-2
Bluff body calculation was accelerated by using a special-purpose computer, MDGRAPE-2, that was exclusively designed for molecular dynamics simulations. The three main issues were solved regarding the implementation of the MDGRAPE-2 on vortex methods. These issues were the efficient calculation of the Biot-Savart and stretching equation, the optimization of the table domain, and the round-off e...
متن کاملMDGRAPE-4: a special-purpose computer system for molecular dynamics simulations
We are developing the MDGRAPE-4, a special-purpose computer system for molecular dynamics (MD) simulations. MDGRAPE-4 is designed to achieve strong scalability for protein MD simulations through the integration of general-purpose cores, dedicated pipelines, memory banks and network interfaces (NIFs) to create a system on chip (SoC). Each SoC has 64 dedicated pipelines that are used for non-bond...
متن کاملAcceleration of Vortex Methods Calculation Using Mdgrape-2 and Mdgrape-3: a Comparative Study
The calculation of vortex method has been accelerated by using special-purpose computers, MDGRAPE-2 and MDGRAPE-3, respectively. The similar algorithm has been implemented and the improvement in speed of MDGRAPE-2 was 100 times while MDGRAPE-3 was 1000 times faster when compared with the ordinary PC Xeon 5160(3.0GHz) for N=10. In addition, the speed of MDGRAPE-3 was 25 times faster compared wit...
متن کاملEffect of uniform magnetic field on dose distribution in the breast radiotherapy
Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...
متن کاملLarge-Scale Nanosecond Simulations of the Dynamics of the Xe + H2O System
Large-scale molecular dynamics simulations of the high-pressure transformations of the xenon/water system were performed involving special purpose molecular dynamics machines. We investigated several systems of different sizes and geometry at the suitable simulational conditions (density, temperature, etc.), which are similar to the experiments conducted on the xenon hydrates. A binary mixture ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IBM Journal of Research and Development
دوره 48 شماره
صفحات -
تاریخ انتشار 2004