Echocardiographic restenosis after successful balloon dilatation of the mitral valve with the Inoue balloon: experience of a United Kingdom centre.
نویسندگان
چکیده
OBJECTIVES (a) To assess the echocardiographic incidence of restenosis after successful balloon dilatation of the mitral valve at a mid-term follow up of one year among a population of predominantly United Kingdom patients. (b) To identify any factors, assessed before or during dilatation, which may predict the development of restenosis. DESIGN Successful dilatation of the mitral valve was defined as an increase in mitral valve area of > 25% and a final valve area of at least 1.5 cm2. Echocardiographic restenosis was defined at follow up as a loss of 50% of initial gain and a valve area of less than 1.5 cm2. Mitral valve area was assessed by transthoracic echocardiography before, during, 48 hours after, and one year after successful balloon dilatation of the mitral valve. Echo score before dilatation (an assessment of valvar and subvalvar calcification, thickening, and mobility), age, rhythm, echocardiographic mitral valve area before and after dilatation, left atrial pressure before and after dilatation, and end diastolic mitral valve gradient before and after dilatation were compared in those patients with and without echocardiographic restenosis at one year. SETTING A regional cardiothoracic centre in the United Kingdom that performs 20-30 balloon dilatations of mitral valves each year. PATIENTS 39 patients, with symptomatic dominant mitral stenosis, who had undergone successful balloon dilatation of the mitral valve, and in whom echocardiographic assessment of mitral valve area was available at one year. 92% of patients were citizens of the United Kingdom. INTERVENTIONS Balloon dilatation of the mitral valve by the Inoue technique. MAIN OUTCOME MEASURES Mitral valve area and patient symptom class (New York Heart Association) one year after successful dilatation of the mitral valve. RESULTS The incidence of echocardiographic restenosis was eight of 39 patients (21%). Of the eight patients with restenosis four underwent mitral valve replacement, two had repeat dilatation of the mitral valve, and two remained on medical treatment. With univariant analysis, factors associated with restenosis were increased age, higher echo score before dilatation, and a lower mitral valve area immediately after the operation. The only independent risk factor for restenosis, shown by multivariant analysis, was a high echo score before dilatation. There was no significant fall in mitral valve area at one year in those patients without restenosis. Most (28/31) of these patients had echocardiographic evidence of splitting of at least one commissure after dilatation compared with only two of eight patients who developed restenosis. Of 10 patients with an echo score before dilatation > or = 10 only two had an initially successful operation and no restenosis at one year. CONCLUSIONS The echocardiographic incidence of restenosis after dilatation of the mitral valve by the Inoue technique in patients of the United Kingdom is 21%. The principal factor associated with restenosis is a high echo score before dilatation. Increases in mitral valve area are maintained in those patients without restenosis and it is likely that the mechanism of initial increase in valve area is different in the two groups, being commissural splitting in those patients who do not get restenosis and valve stretching in those that do. In patients with an echo score > or = 10 dilatation of the mitral valve should be considered only as a palliative procedure.
منابع مشابه
A comparison of cylindrical and Inoue balloon techniques for mitral valvotomy in patients in the United Kingdom.
OBJECTIVES To compare the use of cylindrical balloons and the Inoue balloon for percutaneous mitral valvotomy in patients in the United Kingdom. DESIGN Comparison of the haemodynamic results, complications, and symptomatic outcome of balloon dilatation for mitral stenosis in consecutive patients treated by cylindrical balloons and a second consecutive series of patients treated by the Inoue b...
متن کاملImmediate Results of Percutaneous Mitral Balloon Valvuloplasty in Patients with Mitral Stenosis
Introduction: Mitral stenosis is a prevalent valvular disease in developing countries. Percutaneous mitral balloon valvuloplasty (PMBV) is the gold standard treatment. The main objective of this study was to assess the initial results of PMBV in patients with mitral stenosis during 16 years (2002-2018) in Mashhad, Iran. Materials and Methods: From April 2002 to March 2018, 770 patients underwen...
متن کاملLate clinical and echocardiographic follow up after percutaneous balloon dilatation of the mitral valve.
OBJECTIVE To assess the outcome after attempted percutaneous balloon dilatation of the mitral valve in patients with severe mitral stenosis between February 1986 and June 1992. DESIGN Clinical state, mitral valve area, and restenosis at follow up were analysed. Mitral valve area as determined by the Gorlin formula, planimetry, and Doppler methods was compared before and after dilatation and a...
متن کاملPercutaneous mitral valvoplasty: 30 years of experience.
Mitral Valve; Balloon Dilatation / history. In 1982, Kanjii Inoue, a Japanese cardiac surgeon, developed the concept that a thickened and deteriorated mitral valve could be widened as a synthetic balloon. This concept was similar to the one used in the surgical closed mitral commissurotomy1. Subsequently, the double-balloon technique was introduced in Saudi Arabia as an alternative method to th...
متن کاملMitral balloon valvotomy using the Inoue balloon technique for selected patients with severe pliable rheumatic mitral valve stenosis: immediate and short-term results.
We selected 40 patients with severe symptomatic rheumatic mitral stenosis for balloon valvotomy using the Inoue balloon technique. The patients' mean age was 31 +/- 14 years and there were 24 females and 16 males. The patients were selected according to the following echo/Doppler criteria; 1. Severe mitral stenosis, i. e. mitral valve area (MVA) less than 1.1 cm2; 2. pliable anterior mitral val...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 69 5 شماره
صفحات -
تاریخ انتشار 1993