Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients

نویسندگان

  • Fei Dai
  • Yaoyao Liu
  • Fei Zhang
  • Dong Sun
  • Fei Luo
  • Zehua Zhang
  • Jianzhong Xu
چکیده

OBJECTIVES To describe a new approach for the application of polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws. METHODS Between June 2010 and February 2013, 43 patients with degenerative spinal disease and osteoporosis (T-score <-2.5) underwent lumbar fusion using cement-injectable cannulated pedicle screws. Clinical outcomes were evaluated using a Visual Analog Scale and the Oswestry Disability Index. Patients were given radiographic follow-up examinations after 3, 6, and 12 months and once per year thereafter. RESULTS All patients were followed for a mean of 15.7 ± 5.6 months (range, 6 to 35 months). The Visual Analog Scale and Oswestry Disability Index scores showed a significant reduction in back pain (p = 0.018) and an improvement in lower extremity function (p = 0.025) in patients who underwent lumbar fusion using the novel screw. Intraoperative cement leakage occurred in four patients, but no neurological complications were observed. Radiological observation indicated no loosening or pulling out of the novel screw, and bone fusion was excellent. CONCLUSIONS The described polymethylmethacrylate augmentation technique using bone cement-injectable cannulated pedicle screws can reduce pain and improve spinal dysfunction in osteoporotic patients undergoing osteoporotic spine surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation

Polymethyl methacrylate (PMMA)-augmented cannulated pedicle-screw fixation has been routinely performed for the surgical treatment of lumbar degenerative diseases. Despite its satisfactory clinical outcomes and prevalence, problems and complications associated with high-strength, stiff, and nondegradable PMMA have largely hindered the long-term efficacy and safety of pedicle-screw fixation in o...

متن کامل

Biomechanical Performance of an Injectable Screw for Fixation in Severely Osteoporotic Bone: an Experimental Study

INTRODUCTION Pedicle screw fixation in a severely osteoporotic spine remains a challenge for orthopaedic surgeons. Previous studies have demonstrated that pedicle screw fixation is highly correlated to the bone mineral density [1], and increasing the screw’s pullout strength can be achieved using a variety of methods, these include the use of pedicle screws with various designs [2,3]. However, ...

متن کامل

Pullout performance comparison of pedicle screws based on cement application and design parameters.

Pedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core wit...

متن کامل

Surgical Strategies to Improve Fixation in the Osteoporotic Spine: The Effects of Tapping, Cement Augmentation, and Screw Trajectory

Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw ...

متن کامل

PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine.

BACKGROUND Pedicle screw pullout due to poor bone quality, mainly caused by osteoporosis, is a common problem in spine surgery. Special implants and techniques, especially PMMA augmentation, were developed to improve the fixation of pedicle screws. PMMA injection into a pilot hole or through a screw involves the same risks as vertebroplasty or kyphoplasty, regardless of the technique used. Espe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 70  شماره 

صفحات  -

تاریخ انتشار 2015