A comparison of three commercial IMRT treatment planning systems for selected pediatric cases

نویسندگان

  • Ismail Eldesoky
  • Ehab M. Attalla
  • Wael M. Elshemey
  • Mohamed S. Zaghloul
چکیده

This work aimed at evaluating the performance of three different intensity-modulated radiotherapy (IMRT) treatment planning systems (TPSs)--KonRad, XiO and Prowess--for selected pediatric cases. For this study, 11 pediatric patients with different types of brain, orbit, head and neck cancer were selected. Clinical step-and-shoot IMRT treatment plans were designed for delivery on a Siemens ONCOR accelerator with 82-leaf multileaf collimators (MLCs). Plans were optimized to achieve the same clinical objectives by applying the same beam energy and the same number and direction of beams. The analysis of performance was based on isodose distributions, dose-volume histograms (DVHs) for planning target volume (PTV), the relevant organs at risk (OARs), as well as mean dose (Dmean), maximum dose (Dmax), 95% dose (D₉₅), volume of patient receiving 2 and 5 Gy, total number of segments, monitor units per segment (MU/Segment), and the number of MU/cGy. Treatment delivery time and conformation number were two other evaluation parameters that were considered in this study. Collectively, the Prowess and KonRad plans showed a significant reduction in the number of MUs that varied between 1.8% and 61.5% (p-value = 0.001) for the different cases, compared to XiO. This was reflected in shorter treatment delivery times. The percentage volumes of each patient receiving 2 Gy and 5 Gy were compared for the three TPSs. The general trend was that KonRad had the highest percentage volume, Prowess showed the lowest (p-value = 0.0001). The KonRad achieved better conformality than both of XiO and Prowess. Based on the present results, the three treatment planning systems were efficient in IMRT, yet XiO showed the lowest performance. The three TPSs achieved the treatment goals according to the internationally approved standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases

The aim of this work was to compare different approaches to VMAT optimization (biological vs. physical DVH-based) in two commercial treatment planning systems (TPS) for head and neck and prostate cases, using Pareto fronts. VMAT vs. IMRT Pareto front comparison was additionally performed in order to benchmark the optimizer efficiency and VMAT plan quality for each TPS. Three prostate and three ...

متن کامل

Assessment of out-of-field dose calculation algorithm by commercial treatment planning systems in IMRT and 3DCRT

Abstract Introduction: The accuracy an assessment of out- of- field dose due to secondary cancer risk is clinically important. Actually radiotherapy treatment planning systems are not commissioned for the out-of-field dose calculations, so the estimation of dose distributions by TPSs beyond the borders of treatment fields is not well calculate...

متن کامل

Comparison between field-in-field technique and the use of conventional wedges for treatment planning of esophageal cancer

Introduction: This study was conducted to evaluate and quantify the treatment planning performance of MLC-optimized field-in-field planning technique (FIF), also named forward IMRT, versus wedge-based three field (W3F) technique in terms of dosimetric and radiobiological parameters for esophageal carcinoma.   Material and Methods: Twenty patients with esophag...

متن کامل

Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma

Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012