OBJECTIVES This study was designed to assess whether the spectral waveform of coronary velocity on Doppler study is characteristically altered in the presence of significant stenosis with normalization of the spectral waveform after relief of endolumen obstruction. BACKGROUND Although coronary flow reserve determinations have provided physiologic information complementary to the angiographic percent diameter narrowing, flow velocity measurements have been limited to proximal arteries with inconsistent results after angioplasty. A 12-MHz Doppler guide wire permits flow velocity determination in the proximal and distal coronary artery with fast Fourier spectral analysis. METHODS With the Doppler guide wire, proximal arterial flow velocity and flow reserve measurements in 17 angiographically normal arteries were compared with measurements in 29 significantly stenosed arteries. Proximal and distal flow velocity measurements were also obtained before and after angioplasty of the 29 abnormal arteries. Velocity spectrum was digitized to compute peak diastolic velocity, peak systolic velocity, mean velocity, diastolic/systolic velocity ratio and first third and first half flow fraction. RESULTS Compared with proximal stenosed arteries, proximal normal arteries had significantly higher peak diastolic velocity (64 +/- 26 cm/s vs. 41 +/- 26 cm/s) and higher coronary vasodilator reserve (2.3 +/- 0.8 vs. 1.6 +/- 0.7). Normal arteries had higher flows in the first third and first half of the coronary cycle (46 +/- 3% vs. 39 +/- 7% and 65 +/- 2% vs. 56 +/- 10%, respectively). Before angioplasty, coronary velocity variables were significantly lower distal than proximal to the stenosis. After angioplasty, there was a greater mean increase in distal velocities (200% vs. 90% for the proximal arteries) that resulted in near equalization of proximal and distal mean velocity and a significant reduction in proximal/distal mean velocity ratio (2.4 +/- 1.7 vs. 1.2 +/- 0.4). CONCLUSIONS Before angioplasty, abnormal coronary flow velocity dynamics are more marked distal than proximal to the stenosis. Greater increase in coronary flow velocities in the distal circulation after relief of endolumen obstruction results in a significant reduction in the proximal/distal flow velocity ratio. Thus, normalization of Doppler-derived flow velocity variables with marked reduction of the proximal/distal flow velocity ratios parallels angiographic success and may prove useful as an additional end point measurement in interventional cases with questionable angiographic findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

Coronary flow reserve in the contralateral artery increases after successful coronary angioplasty in patients with spontaneously visible collateral vessels.

OBJECTIVE To test the hypothesis that coronary flow reserve could increase in the angiographically normal contralateral artery after successful coronary angioplasty of an ipsilateral coronary artery. DESIGN Coronary flow reserve was estimated using a Doppler flow guide wire, by giving intracoronary adenosine in the contralateral artery, before and 15 minutes after the end of angioplasty. SE...

متن کامل

Measuring the Nitroglycerine-Induced Vasodilation in Carotid Arteries

Introduction: Nitroglycerin is a fast-acting drug that rapidly dilates coronary arteries and thus increases blood flow to these vessels, and increases the blood flow through the lateral vessels to low blood areas. It also reduces both end diastolic pressure and volume of the left ventricular. However, the effect of nitroglycerin on the circulation hemodynamic is not known. Caro...

متن کامل

Augmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty.

BACKGROUND Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloon...

متن کامل

Augmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary Angioplast

Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 1993