Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

نویسندگان

  • Ilser Turkyilmaz
  • Lars Sennerby
  • Burak Yilmaz
  • Burak Bilecenoglu
  • Esma Nida Ozbek
چکیده

BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction sockets, and to explore the correlations between the peri-implant bone levels and implant stability parameters. MATERIALS AND METHODS Six human cadaver mandibles including all natural teeth were selected for this study. All natural teeth were gently extracted, and 84 implants were immediately placed into fresh extraction sockets with five different implant depths. The maximum insertion torque values were recorded, and primary implant stability measurements were performed by means of resonance frequency analysis (RFA). The vertical distance between implant/abutment junction and the first bone-implant contact was recorded using a periodontal probe. RESULTS It was found that the insertion torque and RFA were 28.9 +/- 7 Ncm and 65.6 +/- 9 implant stability quotient (ISQ), respectively, for 420 measurements from all 84 implants. Statistically significant correlation was found between insertion torque and ISQ values (r = 0.86; p < .001) for all implants. Both insertion torque and ISQ values dramatically decreased when the amount of peri-implant vertical bone defect increased. CONCLUSION The results of this study demonstrated a linear relationship between peri-implant vertical bone defect depth and RFA value. It is proposed that the RFA method is sensitive to detect changes of the marginal bone level and may be used to monitor healing of peri-implant bone defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel implant design for initial stability of dental implants inserted in fresh extraction sockets: a preliminary study.

OBJECTIVES To evaluate a novel implant design for immediate implantation. This implant presents a specially designed expanded diameter midcrestal "wing" thread, which is aimed to provide added bone contact for greater insertion torque and primary stability. METHODS Mandibular premolars were extracted in 2 mongrel dogs, and immediate dental implants were inserted into the fresh extraction sock...

متن کامل

Biomechanical aspects of primary implant stability: a human cadaver study.

BACKGROUND The quality of bone is an important factor in the successful implant treatment, and it is evident that higher implant failure is more likely in poor quality of bone. The primary stability of oral implants related to resistance to micromotion during healing is influenced by bone quality, surgical technique, and implant design. PURPOSES The aims of this biomechanical study were to ex...

متن کامل

Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis

BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...

متن کامل

The influence of insertion torque on the survival of immediately placed and restored single-tooth implants.

PURPOSE The purpose of this retrospective study was to evaluate the medium- to long-term clinical outcome of single-tooth implants placed into fresh extraction sockets using a low-insertion-torque protocol and immediately restored with acrylic resin provisional crowns. MATERIALS AND METHODS Sixty-one patients consecutively referred for the replacement of one or more failing teeth were planned...

متن کامل

Influence of bone density on implant stability parameters and implant success: a retrospective clinical study

BACKGROUND The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient sit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2009