Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields.

نویسندگان

  • C A Bassett
  • S N Mitchell
  • S R Gaston
چکیده

One hundred and twenty-five patients with one hundred and twenty-seven ununited fractures of the tibial diaphysis were treated exclusively with pulsing electromagnetic fields. The over-all success rate in healing of the fracture with this surgically non-invasive out-patient method was 87 per cent. The success rate was not materially affected by the age or sex of the patient, the length of prior disability, the number of previous failed operations, or the presence of infection or metal fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Efficacy of Ununited Tibial Fracture Treatment Using Pulsing Electromagnetic Fields

Thirty ununited tibial fractures with a median time since injury of 18±9 months were treated by electrical stimulation using pulsing electromagnetic field therapy. Union was achieved in 25 cases(83.3%)in a median interval of 8.6±3.2 months. Patient age and gender, the presence of surgical hardware, length of disability, and the number of surgical procedures did not affect the outcome. Ununited ...

متن کامل

The treatment of fibrous non-union of fractures by pulsing electromagnetic stimulation.

Fifty-three ununited fractures with a median time since injury of 28 months were treated by electrical stimulation using pulsing electromagnetic fields. Union was achieved in 38 cases (71.7 per cent) in a median time of six months. For ununited fractures of the tibia the success rate was higher at 86.7 per cent. Previous or active sepsis, the presence of plates or nails, the age of the patient ...

متن کامل

Exchange nailing of ununited fractures.

Exchange nailing is most appropriate for a nonunion without substantial bone loss. There is no clear consensus regarding the use of exchange nailing in the presence of active, purulent infection. The exchange nail should be at least 1 mm larger in diameter than the nail being removed, and it has been recommended that it be up to 4 mm larger when the nail being removed was greatly undersized. Ca...

متن کامل

Operative Management of Fractures Shaft Tibia with Closed Intramedullary Interlocking Nail

Tibial diaphyseal fractures are one of the commonest long bone fractures encountered by most of the orthopaedic surgeons. There are many methods of treatment for tibial diaphyseal fractures. But now-a-days closed intramedullary interlocking nailing is emerging as treatment of choice for all closed tibial diaphyseal fractures, most of type Iand type II open fractures in adults. Closed IM IL nail...

متن کامل

Focus On Tibial fractures

Epidemiology A review of the literature suggests that tibial diaphyseal fractures are declining in incidence in the developed world. Weiss et al1 have shown that the incidence of tibial diaphyseal fractures in Sweden declined from 18.7/105/year in 1998 to 16.1/105/year in 2004. They also found that 48% of fractures were caused by a fall from a standing height, compared with 21% of fractures whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 63 4  شماره 

صفحات  -