Analysis of Flow Rate Through Elastomeric Local Infiltration Analgesia Pumps

نویسنده

  • Anthony Andreas Theodorides
چکیده

Background: Local infiltration analgesia pumps have been increasingly used to provide postoperative pain relief. However, their flow rate over time may not be reliable and accurate which can pose concerns regarding the achievement of the desired therapeutic level. We sought to find out in vitro if the flow rate of two elastomeric infusion pumps when combined with two types of wound catheter is accurate and maintained over 48 hours which is the duration used at our clinical practice. Methods: There were four combinations of pumps and catheter, and each were tested three times. For each test, three pump and catheter combinations were tested at the same time. Flow rate was determined by placing the pumps on digital scales and recording the mass loss of normal saline every 2 hours for 48 hours. Results: None of the pump/catheter combinations achieved the desired 4ml/hr flow rate. There was no combination of pump and catheter that was significantly better than another. All pumps and catheter combinations lost approximately 1ml/hr of flow rate by 48 hours thus making them less reliable and robust in administering fluid accurately. Temperature did not appear to affect flow rate. Conclusion: Elastomeric pumps tested do not achieve the desired flow rate and the flow rate drops over 48 hours.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling

BACKGROUND One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. OBJECTIVES Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an ela...

متن کامل

Disposable infusion pumps.

PURPOSE The properties, performance, and applications of nonelectric disposable infusion pumps are reviewed. SUMMARY All nonelectric disposable infusion pumps exploit the same physical principle: mechanical restriction within the flow path determines the speed of pressurized fluid. The pressure generated by disposable pumps on fluid is 250-600 mm Hg, compared with 5-1200 mm Hg of pressure for...

متن کامل

Comparison of flow rate accuracy and consistency between the on-Q, baxter, and ambu pain infusion devices

AIM: Providing analgesia via peripheral nerve catheters attached to an infusion pump is an effective pain management option in children. METHODS: Portable infusion pumps are being used with increased frequency in pediatric patients. Because these pumps are infusing potentially toxic doses of medications, the accuracy and consistency of these devices becomes very important in this patient popula...

متن کامل

The efficacy of elastomeric patient-control module when connected to a balloon pump for postoperative epidural analgesia

When considering the principles of a pain control strategy by patients, reliable administration of additional bolus doses is important for providing the adequate analgesia and improving patient satisfaction. We compared the efficacy of elastomeric patient-control module (PCM) with conventional PCM providing epidural analgesia postoperatively.A noninferiority comparison was used. Eighty-six pati...

متن کامل

A new, lateral, continuous, combined, femoral–sciatic nerve approach via a single skin puncture for postoperative analgesia in intramedullary tibial nail insertion

BACKGROUND The prevalence of anterior knee pain following intramedullary tibial nail insertion is high. Continuous peripheral nerve blockade is an alternative method of pain control to opiods. This case illustrates the use of femoral nerve and sciatic nerve peripheral catheters with an elastomeric infusion pump for major intramedullary nailing surgery. CASE REPORT A 36-year-old male with frac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017