Phase Error Correction for Synthetic-Aperture Phased-Array Imaging Systems

نویسندگان

  • Michael A. Fiddy
  • Rick P. Millane
چکیده

If one replaces the ordinary single receiver of a synthetic-aperture radar (SAR) with a linear array of receivers underneath the wings of an aircraft, one obtains a 3-D signal history (two spatial dimensions plus the frequency dimension) that allows the computation of a 3-D image (angle-angle-range) of a scene. Because of the limited extent of the wingspan, the cross-track resolution is limited, driving one to use high frequencies, such as 94 GHz, having a wavelength of 3.2 mm. At such short wavelengths, the motion ofthe wings during the synthetic-aperture integration time will cause large phase errors that will severely blur the image. This paper describes an approach to measuring and correcting these and other phase errors. The approach involves having three transmitters, each at a slightly different monotone frequency. Relative to the first receiver, the second is displaced along the direction of the array of receivers and the third is displaced perpendicular to that direction. The array of receivers can separate the three corresponding signals reflected from the ground from one another. We will show mathematical analysis that allows us to determine the phase errors at each receiver from these three signals. It is required either that the three transmitters experience the same phase errors (so they should be rigidly mounted together) or that the phase errors at the three transmitters are measured. No measurement of phase errors on the receivers is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis and Optimization of Synthetic Aperture Ultrasound Imaging Using the Effective Aperture Approach

An effective aperture approach is used as a tool for analysis and parameter optimization of mostly known ultrasound imaging systems phased array systems, compounding systems and synthetic aperture imaging systems. Both characteristics of an imaging system, the effective aperture function and the corresponding two-way radiation pattern, provide information about two of the most important paramet...

متن کامل

Analysis and Optimization of Medical Ultrasound Imaging Using the Effective Aperture Approach

An effective aperture approach is used as a tool for analysis and parameter optimization of mostly known ultrasound imaging systems phased array systems, compounding systems and synthetic aperture imaging systems. Both characteristics of an imaging system, the effective aperture function and the corresponding two-way radiation pattern, provide information about two the most important paramete...

متن کامل

Strip-map Phase Gradient Autofocus

This paper describes a generalisation of the Phase Gradient Autofocus (PGA) algorithm that allows strip-map operation. A standard autofocus technique, PGA, uses prominent points within the target scene to estimate the point spread function of the system. PGA was developed for tomographic mode spotlight synthetic aperture radar (SAR) but has limited applicability for side-scan synthetic aperture...

متن کامل

Three-dimensional Real-time Synthetic Aperture Imaging Using a Rotating Phased Array Transducer

Current 3D real-time imaging is done either with sparse 2D arrays, or with mechanically moved phased arrays. The former results in a poor resolution and contrast due to a limited amount of elements. The latter has the disadvantage of low frame rates due to the sequential acquisition of the volume line-by-line and plane-by-plane. This paper describes an approach which combines mechanically moved...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003