Anode Position and Last Dynode Timing Circuits for Dual-Layer BGO Scintillator With PS-PMT Based Modular PET Detectors

نویسندگان

  • Nan Zhang
  • Christopher J. Thompson
  • Dylan Togane
  • Francois Cayouette
  • Khanh Q. Nguyen
چکیده

New high spatial resolution positron emission tomography (PET) detectors for small animal and breast imaging have been developed. In these detectors, position-sensitive photomultipliers (R7600-C12) and dual-layer pixelated bismuth germanate (BGO) crystals are employed to detect and localize gamma rays. Modified high-voltage dividers with last dynode readout circuits, front-end anode position, and last dynode timing schemes have been investigated and developed for these detectors. Methods for combining four position-sensitive photomultipliers (PS-PMTs) with simple four ( + , and ) outputs have been developed to further simplify the position processing. The front-end circuits are small so they can be fitted into the detector’s structure. A prototype of two detector modules, each having two PS-PMTs with corresponding electronic circuits, has been built for evaluation. The crystal elements of 10 10 in the proximal layer and 9 9 in the distal can be clearly identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce...

متن کامل

Evaluation of Cerium Doped Lutetium Oxyorthosilicate ( LSO ) Scintillation Crystal for PET

A new scintillation crystal, cerium-doped lutetium oxyorthosilicate &SO) was recently discovered a, with light intensity 75 % of NaI(Tl), scintillation decay time of 12 ns (30%) and 42 ns (70%), effective Z of 66, and density of 7.4 glcc. The fast decay time and scintillation light output of LSO are superior to those of BGO for PET and the stopping power of LSO for 511 keV photons is only sligh...

متن کامل

Polymer Scintillator Detectors for Tof-pet with Large Longitudinal Field of View

In this contribution we present a concept of the large acceptance detector systems based on the organic scintillators which in the future may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing predominantly the timing of signals instead of their amplitudes. The time resolution obtainable with plastic scintillators may be better than 1...

متن کامل

Construction and calibration of detectors for high-resolution metabolic breast cancer imaging

Each of two detectors used in our Positron Emission Mammography (PEM) system consists of four 36 mm x 36 mm x 20 mm bismuth germanate (BGO) crystal detector blocks coupled to a crossed-wire anode position-sensitive photomultiplier tube (PS-PMT). To facilitate high spatial-resolution imaging, the crystal blocks have been finely pixelated using a diamond saw. In each detector, 36 x 36 1.9 mm x 1....

متن کامل

First Hybrid Images from a Combined PET and Field-Cycled MRI System

Introduction There is substantial interest in combining functional and anatomical imaging modalities into hybrid systems [1]. Efforts to combine PET and MRI must overcome the incompatibility of conventional PET detectors based on photomultiplier tubes (PMT) with magnetic fields. There are a number of approaches to PET and MRI modify PET detectors to make them compatible with conventional MRI [2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001